6 Assembling and installing

The assembly and installation must be
performed only by skilled personnel.

6.1 Installation

6.1.1 Preparing the Housing
To retrofit the ES-HD-IPM module to Avigilon HD
enclosures, the existing control board, slide and
heater (if equipped) must first be removed.
1.
Remove all electrical connections from the
circuit board (02)
2.
Remove the fixing screws and the circuit
board.
3.
Loosen the screws fastening the internal
supply slide (01).
4.
Move the internal slide by sliding it until the
holes coincide with the slide locking screws.
5.
Remove the internal slide.
6.
The locking screws will be reused to secure
the IPM module, do not discard these.
7.
For ES-HD-HWS or ES-HD-HWS-LG housings,
remove the heater plate (03) by unscrewing
the two fixing screws.
02
Fig. 1
6.1.2 Completing the External
Installation
Refer to the housing manual for details on
installing the cable glands, mounting the brackets
and adjusting the air intake valves.
6.1.3 How to install the camera
Mount the camera using the supplied screws (01)
and spacers (02).
Apply at least one spacer to guarantee electrical
isolation between the slide and the camera.
Position the camera lens close to the glass to
avoid visual interference or optical reflections.
Connect the camera to the J2 connector (PoE
OUT) with the supplied cable (03).
Fig. 2
Refit the slide in its housing and fix the previously
01
loosened screws.
03
Fig. 3
It is possible to install only PoE type
cameras.
03
01
02
5