6.1.4 PoE cable connection
Connect the PoE cable from the Power Injector to
the J1 connector.
Fig. 3
Before powering the device, you must set the
maximum power consumption of the housing
operating on dip switch SW1 (7 Configuration,
page 8).
6.1.5 Connection of the blower for
ES-HD-CWS and ES-HD-CWS-LG
Connect the fan cable to the J4 connector.
Fig. 4
6
7 Configuration
Before powering the device, you must set the
maximum power consumption of the housing
operating on dip switch SW1.
Fig. 5
ABSORBED POWER CONFIGURATION
SW1
OFF
ON
Tab. 1
According to the absorbed power, the system can
supply the options described in the table (Tab. 3,
page 9).
Maximum power
PoE class 3 (13W max)
Hi-PoE class 4 (25W max)