5
Accuracy
Telescope
Compensator
Distance measure-
ment
Circular level
Circle
Adaption
Environmental
Specifications
NA520/24/32, Technical Data
Technical Data
Standard deviation for 1 km double levelling ISO17123-2:
NA520:
2.5 mm
NA524:
1.9 mm
NA532:
1.6 mm
Erect image
Magnification
NA520:
NA524:
NA532:
Field of view:
Shortest target distance
from instrument axis:
Working range:
Setting accuracy
(standard deviation):
Multiplication factor:
Additive constant:
Sensitivity:
Graduation:
Graduation interval:
To normal or ball head tripod
Central fixing screw:
Temperature
Operating temperature
-20°C to +50°C
(-4°F to +122°F)
Protection against water, dust and sand
Protection
IP56 (IEC 60529)
20 x
24 x
32 x
< 2.1 m at 100 m
< 1.0 m
±15'
0.5''
100
0
8'/2 mm
360°
1°
5/8''
Storage temperature
-40°C to +70°C
(-40°F to +158°F)
en
12