Maintenance
Change the Sensor Battery
a. Lift the tab on the top of the Sensor and remove the cover. (See Step 1 for diagrams.)
b. Remove old battery. Use care to avoid touching circuit board when handling battery.
c. Insert a new 3V CR123A battery. Observe polarity.
d. Replace the Sensor cover.
Note: Sensor enrollment is not required after battery change.
Note: Failure to properly and timely change battery will impair sensor performance.
Adjust Pet Immunity Setting or Motion Reset Time
Pet Immunity factory default is PET1. Motion Reset Time factory default is four-minute setting.
a. Remove the Sensor cover as shown at Step 1.
b. Change position of the circuit board jumper as shown below.
c. Replace the Sensor cover.
Pet Immunity Settings
Jumper
Jumper removed from
PET1/PET2 connectors for
highest sensitivity
If necessary to remove a Sensor from the Nexia account, follow these steps to exclude the Sensor from a
Z-Wave Network:
a. Hold the Nexia Bridge within 6 feet (1.8 meters) of the Sensor during the entire exclusion process.
b. Press and release the "–" button on the Bridge.
c. Use a pin or paper clip to press the program button on the back of the Sensor case.
d. Observe lights on the Bridge. The orange light will blink while exclusion is taking place. Exclusion is complete when the orange light
becomes solid.
e. Remove the battery from the Sensor after exclusion is complete.
For more information, refer to the Nexia Bridge Users Guide.
Orange LED
– Button
FCC Statement
This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must
accept any interference received, including interference that may cause undesired operation.
Changes or modifi cations to this equipment not expressly approved by the Schlage Lock Company could void the user's authority to operate the equipment.
nexiahome.com
U.S.A. /Canada
(877) 288-7707
Jumper
Jumper on PET1 connector
Jumper on PET2 connector
for medium sensitivity
for lowest sensitivity (large
(small animal not detected)
animal not detected)
Motion Reset Time Settings
Jumper
Jumper on one pin of the
TEST connector for four
minute motion reset time
SAFETY HAZARD!
BATTERY MAY EXPLODE IF
NOT PROPERLY HANDLED.
DO NOT RECHARGE,
DISASSEMBLE OR DISPOSE
OF IN FIRE.
Jumper
Jumper
Jumper on both pins of the
TEST connector for fi ve
second motion reset time
© 2012 Ingersoll Rand
P516-486 Online Rev 05/12-a