Troubleshooting - Dometic FreshWell 3000 Instrucciones De Montaje

Equipo de aire condicionado de cajon
Ocultar thumbs Ver también para FreshWell 3000:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 54

Troubleshooting

8
Troubleshooting
Problem
Cause
No cooling
The under-bench air conditioner is
capacity
not set to cooling.
The ambient temperature is above
52 °C.
The temperature set is higher that the
room temperature.
The ambient temperature is below
16 °C.
The thermal protection is defective.
The compressor is damaged.
The refrigerating agent filling is
insufficient.
The heat exchange coils are polluted.
The external blower is defective.
No heating
The under-bench air conditioner is
capacity
not set to heating.
The ambient temperature is below
0 °C.
The temperature set is lower than the
room temperature.
The ambient temperature is higher
than 31 °C.
The thermal protection is defective.
The compressor is damaged.
The refrigerating agent filling is
insufficient.
The heat exchange coils are polluted.
The external blower is defective.
Low air output
The air filter is obstructed.
The heat exchange coils are polluted. ➤ Contact an authorised work-
The internal blower is defective.
14
Dometic FreshWell3000
Remedy
➤ Set the under-bench air condi-
tioner to cooling.
The under-bench air conditioner is
only designed for ambient temper-
atures of up to 52 °C.
➤ Select a lower temperature.
The under-bench air conditioner is
only designed for ambient temper-
atures above 16 °C.
➤ Contact an authorised work-
shop.
➤ Set the under-bench air condi-
tioner to heating.
The under-bench air conditioner is
only designed for ambient temper-
atures higher than 0 °C.
➤ Select a higher temperature.
The temperature is adjustable
between 16 °C and 31 °C.
➤ Contact an authorised work-
shop.
➤ Clean the air filter.
shop.
EN

Publicidad

Tabla de contenido

Solución de problemas

loading

Este manual también es adecuado para:

Freshwell3000

Tabla de contenido