Actuador regulador radioeléctrico de 1 elemento mini
Switchoff delay
Dim up ramp
Dim down ramp
Dimming adjustment time
Runon time
Behaviour after the end of the
disabling function
32580702
10499446
0 s ... 24 h
Basic setting: 0 s
0 s ... 24 h
Basic setting: 0 s
0 s ... 24 h
Basic setting: 0 s
1...60 s
Basic setting: 4 s
0 s ... 24 h
Basic setting: 0 s
On
Off
no change
Last value
Basic setting: No change
12.03.2014
The load switches off after a
delay. Repeated switchoff
commands restart the delay ti
me. If the load has not yet
been switched off due to the
delay when a switchon com
mand comes, then the load
will remain on.
Note: The set time apply to
operation using radio transmit
ters. The device is switched
immediately when the Prog
button is pressed.
Time between switchon and
reaching switchon brightness.
The light is switched on at mi
nimum brightness and then
dimmed to the switchon brig
htness.
Only applies to switchon with
transmitters (short operation).
If scenes are recalled or swit
ching uses logic modules, the
switchon brightness is ap
proached using socalled soft
dimming (not configurable).
Time until reaching minimum
brightness. The light is dim
med to minimum brightness
and then switched off.
Only applies to switchoff with
transmitters (short operation).
If scenes are recalled or swit
ching uses logic modules, the
system switches off directly.
Time from minimum bright
ness until reaching maximum
brightness (dimming speed).
As soon as a runon time has
been entered, the actuator will
no longer remain on perma
nently, but only for the length
of the runon time. The runon
time is restarted if actuation is
repeated. This parameter is di
rectly connected to the "Ma
nual switchoff of runon time"
parameter.
Note: The set time apply to
operation using radio transmit
ters. The device is switched
immediately when the Prog
button is pressed.
Behaviour of the output when
a block is removed.
9/15