3
STARTING A VEHICLE
Make sure that Enerjump Truck is properly charged (the number of the indicator lights must be not less
than 3).
• Turn off all the accessories on the vehicle.
• Connect the red battery clamp of the jumper cable to the vehicle's positive (+) battery terminal and
connect the black battery clamp to the vehicle's negative (-) battery terminal. Warning: pay attention
to the polarity!
The product will automatically identify the 12V/24V auto voltage (Smart Jump Start System™)*.
• Turn the ignition key to start the vehicle.
• If the engine starts, disconnect the red and black clamps from the vehicle's battery terminal within 30
seconds.
• Leave the vehicle's engine running for a few minutes.
• If the vehicle does not start on the fi rst trial, wait for 1 minute before trying to start the vehicle again.
* If the product will NOT automatically identify the 12V/24V auto voltage please proceed as follows :
• Check the connection of the Enerjump Truck clamps to the battery of the vehicle.
• If the product doesn't recognize the auto voltage automatically, keep pressed the 12/24V Switch ac-
cordingly to the vehicle battery type.
NOTE: This procedure will disable the Smart Jump Start System™ (see point before).
• If still no Jump Start Reaction after the above steps, please check the vehicle to see if other problem
happens.
TROUBLE SHOOTING
PROBLEM
12V/24V indicators are blinking
12V/24V indicators are blinking
when connected to vehicle's
battery
10
1
2
4 5
12/24V
CAUSES
Self protection against short cir-
cuits
Self protection against polarity
inversion.
6
12/24V
CORRECTIVE ACTION
Unlock Enerjump Truck by pu-
shing the Switch Test for 5 se-
conds after the short circuit has
been removed.
Check if the Red and Black
clamps are connected in the
proper mode.