CONTROL PANEL
Perform the electrical connections to the terminal board,
then supply power to the system: the unit will check the
operation status of the display, by turning all the segments on
for 1,5 seconds (8.8.8.8); after this, the display will show the
firmware version for 1,5 seconds, for instance Pr 2.8.
Now, the display will show a control panel:
The control panel represents the physical status of the
terminal board contacts and of the program mode keys: if
the upper vertical segment is on, the contact is closed; if
the lower vertical segment is on, the contact is open (the
above picture shows an instance where the inputs START,
START P, PHOTO1, PHOTO2, and STOP have all been
correctly connected).
AUTO POWER-OFF FUNCTION:, after 50 seconds from the
last intervention the display goes off. It goes on again at
the first change of any input (START, START P, FOTO1,
FOTO2, STOP) or at the first radio reception of a stored
code. If you push one of the three push buttons (MENU, UP,
DOWN) the display will stay on for 50 seconds.
PROGRAMMING
The PD1 unit presents a programming structure with
menus, each of which corresponds to a function in the unit
(function menu) or to a working time setting (time menu).
Time menus allow adjusting the unit working times (e.g.:
leaf opening or closing time, locking time, preflashing time,
etc.), which can be set from 0 to 120 seconds with a ±0,5
seconds interval.
On the other side, the function menu are used to activate
the required functions (e.g. timed lights, PHOTO1 active as
a travelling edge, PHOTO2 inactive, etc.).
Some time menus depend on certain function menus (e.g.:
if the AUTOMATIC CLOSING is activated – but only in this
case – a TIME-OUT need to be set); then, to simplify the
programming, these time menus have been placed in the
function menus on which they depend. Specifically, menus
AUTOMATIC CLOSING (Ch.AU), ANTISKID (ASM), and
PHOTOCELL TIME-OUT (Ft.PA) offer some "time menus"
among the selectable options.
FUNCTION OF KEYS
MENU, UP, DOWN
To activate the program mode, proceed as follows.
•
After powering the unit, the display should show the
control panel (therefore, check that the connections
made are correct).
•
Press and hold key MENU until the display shows dEF.
Now the program mode is activated: if no action is performed
within 1 minute, the unit will exit the program mode and show
the control panel again.
When the program mode function is activated, press key UP
or DOWN to select the menus, thus performing a forward or
backward shift (for a fast shift, press and hold).
Press key MENU to access the settings in order to change
them through keys UP and DOWN.
•
Pressing the UP key, the menu functions can be scrolled
from below.
•
Pressing the DOWN key, the menu functions can be
scrolled from above.
•
Pressing the MENU key, the settings to be changed can
be accessed and selected by pressing again.
ATTENTION: when the program mode function is not
activated, pressing of the UP key corresponds to the START
command, pressing of the DOWN key corresponds to the
PEDESTRIAN START command: this way, the service
engineer is enabled to perform the test and the set-up.
The PD1 unit can be set up in two different program modes:
DEFAULT PROGRAM MODE or CUSTOM PROGRAM MODE.
In the following pages you can find a functions diagram with
information concerning PD5.
For the use of the function chart proceed as follow:
•
Press DOWN key to flow the chart from the top to the
bottom. The functions dEF, t.AP1, t.AP2 etc.. will be
appear.
•
Press UP key to flow the chart from the bottom to the
top.
•
Press MENU key to flow the chart horizontally; for
example, if the t.ChP function is displayed, by pressing
the MENU key the number 7.0 will be dispayed.
Increase the number pressing UP or DOWN. Press
MENU to display function t.ChP again.
DOWN
18
MENU
UP