Current measurement DC
1. Set the rotary switch to 66 A or 1000 A .Display shows DC. Start with 1000
A when the value is unknown.
2. Open the jaws and center one of the conductor. Make sure the conductor is
placed at center of the jaw. Only one conductor at each time can be measured.
The measured value shows on the display.
Note.
If the meter not display 00,00 when it is at 66 A range press zero
button to zeroing.
When the meter is at 1000 A range it displays 0 and it is not allowed to press
zero button.
Current measurement AC
1. Set the rotary switch to 66 A~ or 1000 A~ .Display shows AC. Start with 1000
A when the value is unknown.
2. Open the jaws and center one of the conductor. Make sure the conductor is
placed at center of the jaw. Only one conductor at each time can be measured.
The measured value shows on the display.
Surge current measurement
1. Set the rotary switch to 1000 A~ .
2. Press select button when the meter display minimum reading. The display
value shows ---- and INRUSH symbol.
(See fig 3).
(See fig 3).