4
3

Keypad

1. operating mode LED
2. button to switch lasers

Operation

1. Set the instrument on the floor or tripod. If you use the tripod,
place the bottom part of the instrument on the tripod and twist
the screw of the tripod into the center hole of the instrument.
2. Switch on the instrument: turn the compensator switch (4)
to the position "ON". Turn the compensator switch (4) to the
position "OFF", to switch off the instrument. If there are no laser
lines when switching on the instrument, it means that the devia-
tion of the instrument from the horizontal plane is more than +-4
degrees. Level the instrument before operation.
3. Laser level can project horizontal and vertical lines. Press
button (1) to switch on the horizontal line. LED mode (2) lights
up green.
Press button (1) one more time to switch on the vertical line. LED
mode (2) lights up red.
Press button (1) for the third time to switch on horizontal and ver-
tical lines. LED mode (2) lights up orange.
Press button (1) for the forth time to switch on the tilt mode. LED
mode (2) lights up orange.
It is possible to fix the pendulum in this mode to turn the switch
ON/OFF up.
It is possible to turn on this mode when the pendulum is locked.
Press button (1) 4 times. To turn it off press button (1) one more time.
Press button (1) for the fifth time to switch off all laser lines. LED
mode (2) blinks off.
4. Use laser glasses (are not supplied with the instrument) or turn
on the detector mode when operating in bright illumination.
Press and hold button (1) for more than 3 sec to turn on the detec-

Publicidad