Preset temperature version (figure 8)
– Remove the plug (5).
– Put the temperature adjustment handle in place and adjust the temperature by turning the handle.
– Turn the handle anti-clockwise for a lower maximum temperature.
Troubleshooting
Symptom
No water comes from the faucet
Water flow does not stop
Flow rate has diminished
Temperature cannot be adjusted
Installation instructions for spare parts
Changing the solenoid valve (figure 12)
– Close the water inlet to the faucet.
– Change the solenoid valve (7) for a new one as shown in the figure.
Cleaning/changing the solenoid valve membrane (figure 13)
– Close the water inlet to the faucet.
– Clean the membrane (8) or if necessary change for a new one as shown in the figure.
Changing the mixer (figure 14)
– Close the water inlet to the faucet.
– Change the mixer (9) for a new one as shown in the figure.
Changing the sensor (figure 15)
– Close the water inlet to the faucet.
– Open the power-source box cover (10) and detach the sensor's connector.
– Change the sensor (11) for a new one as shown in the figure.
Cause/solution
– Check the water inlet to the faucet
– Aerator is blocked
– Litter filters are blocked
– Power failure (230 V)
– Solenoid valve is damaged
– Sensor lenses are dirty
– Solenoid valve membrane is dirty
– Solenoid valve is damaged
– Water supply has been decreased
– Aerator is dirty
– Litter filters are dirty
– Mixer is damaged
– Litter filters are dirty
15