Troubleshooting; Spare Parts - Oras Electra 6220F Guía De Instalación Y Mantenimiento

Ocultar thumbs Ver también para Electra 6220F:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 30
All manuals and user guides at all-guides.com

Troubleshooting

Symptom
No water comes from the faucet
Water flow does not stop
Flow rate has diminished
Temperature cannot be adjusted

Spare parts

(figure 9)
Spare part
Power-source box
Solenoid valve membrane
Pilot solenoid valve
Sensor
Aerator
Litter filter/one-way valve
Mixer
Plug
Installation instructions for spare parts
Changing the solenoid valve
– Close the water inlet to the faucet.
– Change the solenoid valve (7) for a new one as shown in the figure.
Cleaning/changing the solenoid valve membrane
– Close the water inlet to the faucet.
– Clean the membrane (8) or if necessary change for a new one as shown in the figure.
Changing the mixer
– Close the water inlet to the faucet.
– Change the mixer (9) for a new one as shown in the figure.
Changing the sensor
– Close the water inlet to the faucet.
– Open the power-source box cover (10) and detach the sensor's connector.
– Change the sensor (11) for a new one as shown in the figure.
Cause/solution
– Check the water inlet to the faucet
– Aerator is blocked
– Litter filters are blocked
– Power failure (230 V)
– Solenoid valve is damaged
– Sensor lenses are dirty
– Solenoid valve membrane is dirty
– Solenoid valve is damaged
– Water supply has been decreased
– Aerator is dirty
– Litter filters are dirty
– Mixer is damaged
– Litter filters are dirty
Spare part no.
198 693
198 298V
198 819V
198 682V
198 692
198 473/2
198 484V
198 485V
(figure 12)
(figure 14)
(figure 15)
11
(figure 13)

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Electra 6220g

Tabla de contenido