sured directly.
Press button (2) 3 times. The symbol "triangle" is displayed.
The distance to be measured is blinking in the symbol triangle.
Press button (1) to take distance measuring (hypothenuse of
triangle). The result is displayed in the second line. This mea-
surement can be taken in the indirect measurement function.
Press and hold button (1) for 2 sec. After second pressure
of the button (1) value is fixed. The second distance to be
measured is blinking in the symbol triangle. Press button (1)
to take distance measuring. There is a right angle between
laser beam and the length you need to measure. The result of
the measurement is displayed in the second line. The result
of the function is displayed in the first line.

MESSAGE CODES

All message codes are displayed with either "Info". Following
mistakes can be corrected.
INFO
CAUSE
204
Data overflow
205
Measurement
range transfinite
252
Temperature too
high
253
Temperature too low
255
Receiver signal is
too weak
256
Received signal too
strong
206
Pythagorean mea-
surement violation
258
Initialization error
REMEDY
Repeat procedure
Use the meter in distance allowed
Let device cool down
Warm device up
Measure target point with stronger
reflector
Measure target point with weaker
reflector
Re-measure and ensure the hypot-
enuse is
greater than right angle edge
Switch on – off the instrument