• Read the manually carefully in all its
parts before using the product.
• K e e p t h i s m a n u a l f o r f u r t h e r
consultation.
• The manual is intended for different
models and versions, so the product
may look different from the manual
illustrations. However the instructions
remain unchanged.
• The company reserves the right to
make any changes considered suitable
without notice or replacement.
• This product is intended only for the
use for which it has been designed. The
manufacturer is not responsible for any
damage caused by improper use.
• The product identification data (model,
power, voltage, manufacturer's name)
are contained in the silver data plate
on the unit. It is issued at the time of
testing.
• Make sure that the drain is always
efficient.
• Make sure that the floor is always clean
and dry to avoid slipping and falling.
• To avoid accidents make sure that
children and the disabled cannot use
the bathtub unless they are constantly
attended.
• It is not advisable to use the bathtub
with water that is too hot. Use water
with a maximum temperature of 38°C.
• People affected by obesity, heart trouble
or blood pressure disorders, circulation
problems, diabetes, elderly people
or pregnant women should consult a
doctor before using the bathtub.
• People who take medicines should
consult a doctor before using the
bathtub as some medicines may cause
sleepiness, affect heart beat, blood
pressure and circulation.
• Do not use alcoholic substances, drugs
or medicines before and during the
use of the bathtub because they could
cause a loss of conscience.
• The sauna must not be used by
people affected by cardiopathies, inner
inflammations, infectious diseases,
epilepsy and who have pacemakers.
• When the hydrocabin is not used,
disconnect it by switching off the
double-pole switch installed before the
appliance.
All measurements are in mm
INSTALLATION PREPARATIONS
A floor bearing a maximum load of 200 Kg/
m² is necessary, and the room where the
appliance is installed must therefore satisfy
this requirement.
To prevent damaging the mixer parts, fit a
filter upstream of the mixer.
TECHNICAL INFORMATION:
• Minimum flow pressure:
120 kPa (1,2 bar)
• Operating pressure:
350 kPa (max 3,5 bar)
• Recommended operating pressure:
250 kPa (2,5 bar)
• Test pressure:
1,5 MPa (15 bar)
• Hot water temperature:
max 60°C
The power supply box for the wall [to be
connected to point C.V. (see installation
preparations) is supplied in all versions
except the manual version.
To make the electrical connection to
the power supply box (only for product
versions supplied with the power supply
box) use an H07 RN-F cable with diameter
of 2.5 mm².
When making the connection to the
electrical mains, a double-pole switch must
also be fitted near the appliance, upstream
of the power supply box, with contacts
opening by at least 3 mm, and suitable for
220/240 V 16 A.
The appliance must be connected to an
electrical system provided with a 0.03 A
differential thermal breaker.
The supporting structure of the appliance
is metallic. An efficient earthing system is
therefore required, with sensitivity meeting
the relevant standards.
EARTH WIRE.
The earth wire must be connected
and fixed permanently to the electrical
system.
EQUIPOTENTIAL BONDING.
The equipment must be connected
to the equipotential system of the
room and duly fastened to the relative
terminal to be found in the product.
The following accessories not supplied
by the manufacturer are required for
installation:
a) Fittings for connecting the mixer to the
domestic water mains (connection to
mixer via ½" fittings).
b) fittings needed to connect the sunken
drainage to the drain column of the bath
(connection to waste column with 1 ½"
collar waste trap)
5
GB