Troubleshooting Guide; Technical Service - Desa JourneyMan HD-9240 Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Troubleshooting Guide

SYMPTOM
POSSIBLE CAUSE
Lights will
1. Light switch is turned off.
not come
2. Flood light is loose or burned out.
on.
3. Fuse is blown or circuit breaker is
turned off.
4. Daylight turnoff is in effect. (Re-
check after dark) .
5. Incorrect circuit wiring, if this is a
new installation.
6. Re-aim the sensor to cover de-
sired area.
Lights come
1. Control may be installed in a rela-
on in
tively dark location.
daylight.
2. Control is in Test. (Set control
switch to an ON-TIME position) .
Lights come
1. Control may be sensing small ani-
on for no
mals or automobile traffic. (Re-
apparent
aim sensor or use lens shield) .
reason.
2. Sensitivity is set too high. (Reduce
sensitivity. Turn Range Boost off) .

Technical Service

If you experience a problem, follow this guide. You may also want to visit our Web site at: www.desatech.com. If the problem
persists, call* for assistance at 1-800-858-8501, 7:30 AM to 4:30 PM CST (M-F). You may also write* to:
DESA Specialty Products™
P.O. Box 90004, Bowling Green, KY 42102-9004
* If contacting Technical Service, please have the following information available: Model Number, Date of Purchase,
and Place of Purchase.
595-5631-07
(Do Not Send Products)
No Service Parts Available for this Product
SYMPTOM
POSSIBLE CAUSE
Lights stay
1. A lamp is positioned too close to
on continu-
ously.
2. Control is pointed at a heat source
Lights flash
1. Heat or light from the lamps may be
on and off.
2. Reflected heat from other objects
3. Control is warming up. (Flashing is
4. Control is in Test. (Set control switch
-13-
the sensor or pointed at objects
that causes the sensor to trigger.
(Aim the lamp away from the sen-
sor or objects).
like an air vent, dryer vent, or brightly-
painted heat-reflective surface. (Re-
aim sensor. Turn Boost off).
turning the Light Control on and off.
(Aim lamps away from the sensor.
Turn Boost off) .
are triggering the sensor. (Re-aim
sensor. Turn Boost off) .
normal under these conditions. Wait
1 minute for sensor to warm up) .
to an ON-TIME position) .

Publicidad