PROPERTIES OF THE TOOL
The welder is a tool designed for connecting pipes and connecting elements made of thermoplastic materials through welding. The
tool permits quick and comfortable work while building water pipelines. The tool has been designed exclusively for domestic use
and must not be applied for professional purposes, i.e. in factories or for profitable jobs. A correct, reliable and safe functioning of
the grinder depends upon its adequate operation, and therefore:
Before you proceed to use the tool, read the whole manual and keep it.
The supplier shall not be held responsible for any damage due to failure to observe safety regulations and the recommendations
included in this manual. Improper use of the tool also cancels the rights of the user implied by the warranty and related to breach
of the sales contract.
EQUIPMENT
The welder is provided complete and it does not require assembly. The welder is provided with pipe adapters and a support.
TECHNICAL PARAMETRES
Parameter
Catalogue number
Mains voltage
Mains frequency
Nominal power
Surface temperature of pipe adapters
Mass
Working temperature range
Electric insulation class
Protection grade
Welding parameters table in accordance with the pipe diameter
Pipe diameter
[mm]
16
20
25
32
40
50
63
In case work is carried out at the temperature within the range between 0 and 5
GENERAL SAFETY CONDITIONS
NOTE! Get acquainted with all the instructions below. Failure to observe them may lead to an electric shock, fire or injuries. The
notion of electric tool used in the instructions applies to all the tools which are powered with electric current, both wire tools and
wireless ones.
OBSERVE THE FOLLOWING INSTRUCTIONS
Place of work
The place of work must be properly illuminated and clean. Disorder and poor illumination may be a cause of accidents. Do
not work with electric tools in explosive environments, or those which contain inflammable liquids, gases or vapours.
Electric tools generate sparks, which may cause a fire in case of contact with inflammable gases or vapours.
Do not allow children and outsiders to the place of work. A lack of concentration may result in a loss of control over the tool.
Electric safety
The plug of the power supply cable must fit the mains socket. Do not modify the plug. Do not use any adapters whatso-
ever in order to adapt the plug to the socket. Unmodified plug which fits the socket reduces the risk of an electric shock.
O R I G I N A L
10
GB
Unit of measurement
[V]
[Hz]
[W]
[
O
C]
[kg]
[
C]
O
Heating time (approximate)
[s]
8
10
14
16
24
36
48
C, the heating time must be extended by 50%.
O
I N S T R U C T I O N S
Depth of pipe heating
[mm]
12
14
16
20
21
22,5
24
Value
YT-82250
~230
50
850
0 - 300
0,94
0 - 40
I
IPX4
Cooling time for bonds
[min]
3
3
3
4
4
5
6