5 | Status / Error message table
5
Status / Error message table
Screen
LED "Alive"
AAA Under-
1x flashing,
voltage
pause...
A09
2x flashing,
Cabin supply
pause...
air
temperature
sensor
A10
3x flashing,
Cold water
pause...
temperature
sensor
A60
4x flashing,
Internal air
pause...
temperature
sensor
A61
6x flashing,
Air flow rate
pause...
A62
7x flashing,
High air tem-
pause...
perature sup-
ply
A63
8x flashing,
Low air tem-
pause...
perature sup-
ply
A64
9x flashing,
Undercooling
pause...
protection
A65
23x flashing,
Filter service
pause...
Init
5x flashing,
Data commu-
pause...
nication
6 / 52
Possible cause
Switch-off as a result of under-
voltage. The power supply is below
the set undervoltage value for longer
than 5 seconds. This may be caused
by an excessively long cable, over-
loading or an insufficiently high
power-generator output.
l Cabin supply air temperature
sensor defective
l Break/ short-circuit in electrical
circuit
l Temperature sensor not connec-
ted
l Cold water temperature sensor
defective
l Break/ short-circuit in electrical
circuit
l Temperature sensor not connec-
ted
l Internal air temperature sensor
defective
l Break/ short-circuit in electrical
circuit
l temperature sensor not connec-
ted
l Air flow interrupted
l Air flow paths or filters blocked
l Fan inactive
l Outdoor temperature too high
l Cooling capacity insufficient
l Outdoor temperature too low
l Heating capacity insufficient
l Outdoor temperature too low
l Heating capacity insufficient
Filter replacement interval expired
l Initialization procedure or sys-
tem blocked
l Electrical wiring defective
l Interruption in power circuit/
short circuit
Possible cause
Provide a more suitable power supply.
If this does not solve the problem, please contact your au-
thorised Webasto Marine dealer or service partner.
Please contact your authorised Webasto Marine dealer or
service partner.
Please contact your authorised Webasto Marine dealer or
service partner.
Please contact your authorised Webasto Marine dealer or
service partner.
Please contact your authorised Webasto Marine dealer or
service partner.
Switch on the refrigeration system, check cooling mode,
check flow, bleed water circuit, deactivate ECO mode for V
series, switch off air handler in unused cabins. Check the
electric heater's power supply.
Switch on the refrigeration system, check heating mode,
check diesel heater, check flow, bleed water circuit, deactiv-
ate ECO mode for V series, switch off air handler in unused
cabins. Check the electric heater's power supply.
Switch on the refrigeration system, check heating mode,
check diesel heater, check flow, bleed water circuit, deactiv-
ate ECO mode for V series, switch off air handler in unused
cabins. Check the electric heater's power supply.
Please contact your authorised Webasto Marine dealer or
service partner.
Please contact your authorised Webasto Marine dealer or
service partner.
2510284A OI BlueCool F-Series