NO TE: Thoroughly clean and remove debris from the water supply pipe before
installation. This will prevent clogging the spray outlet.
1) Plumb 1/2" NPT nipple so that it extends between 3/8" and 7/8" from the fin-
ished wall.
2) Slide the escutcheon out of the valve body.
3) Wrap an adequate amount of pipe tape around the thread of the 1/2" NPT
nipple.
4) Thread the body onto the 1/2" nipple. Then tighten the cap so that the gasket is
pressed against the wall.
5) Slide the escutcheon back onto the body and press it against the wall.
6) Install the hose and handshower.
7) Install the handle onto the adapter and secure it with the set screw.
NO TE for TS970F1: The knob must be disassembled prior to installation. Remove
the cover, lever and set screws in the order show, then install the knob onto
the adapter. Secure the knob with the large set screw then screw in the lever
and secure it with the small set screw. Replace the cover.
Operation Guide:
To turn on the faucet, turn clockwise. To turn it off, turn counterclockwise.
Adapter
Screw
Escutcheon
Handle
Set Screw
Hex Wrench
INSTALLATION PROCEDURE
Cap
Body
Extension
Lock Nut
Packing
Showerhead
Hose
4
Finished
Shower Wall
1/2" NPT
Nipple
4
2
3
1
1. Cover
2. Small Screw
3. Lever
4. Large Screw