Operation anomalies
The hood does not work
Make sure that:
There is no current blackout
A speed has been effectively selected.
The panel is correctly hooked.
The 9-pole connection is well inserted (Picture 9b).
The red reset key above the electric system box is
pressed.
The wires in the 9-pole connection are well inserted into
the connector. (During connection, exerting an
overpressure may cause the contacts to bend).
The hood has low efficiency
Make sure that:
The motor speed selected is sufficient for the quantity of
fumes present
The kitchen is aired enough to allow an air intake and the
charcoal filter is not worn out (filter version hood).
The air outlet pipe is not clogged.
The suction unit non-return valves can rotate freely.
The hood stops during operation
Make sure that:
There is no current blackout
The differential magnetothermal switch (automatic circuit
breaker) has not been released.
Maintenance
Cleaning
Clean using ONLY the cloth dampened with neutral liquid
detergent.
DO
INSTRUMENTS. Do not use abrasive products. DO NOT USE
ALCOHOL!
Grease filter
Traps cooking grease particles.
This must be cleaned once a month (or when the filter
saturation indication system – if envisaged on the model in
possession – indicates this necessity) using non aggressive
detergents, either by hand or in the dishwasher, which must
be set to a low temperature and a short cycle.
When washed in a dishwasher, the grease filter may discolor
slightly, but this does not affect its filtering capacity.
When inserting and removing grease filters and charcoal
filters, please make sure that the extractable unit of the hood
is in open position .In order to do this,pull the OFF (T5)key.
Then remove the front panel ,by pulling on the upper part of
each side at the same time (Fig.13).
The panel turns forward ,so that grease filters can be inserted
(Fig.14).
Charcoal filter (filter version only)
It absorbs unpleasant odors caused by cooking.
The saturation of the charcoal filter occurs after more or less
prolonged use, depending on the type of cooking and the
regularity of cleaning of the grease filter.
In any case it is necessary to replace the cartridge at least
every four months.
The charcoal filter may NOT be washed or regenerated.
After removing the grease filter, it is possible to insert the
charcoal filters (Fig. 15) (not supplied).
Replacing lamps
(Depending on the model available).Disconnect the appliance
from the electricity.
Warning! Prior to touching the light bulbs ensure they are
cooled down.
Replace the old light bulb with the one of the same type as
specified in the feature label or near the light lamp on the
hood.
To replace the neon proceed as follows:
1.
Lift the trolley.
2.
Disconnect from power supply. (this operation can be
carried out by disconnecting the plug, if accessible, or
open the switch if envisaged during installation or press
the red button in the control box (Fig. 10c)
3.
Remove the screws which fix the upper front as shown in
(Fig. 16)
4.
Lift the upper front (Fig. 17)
5.
Remove the damaged neon (Fig. 18) and replace it with
one having the same characteristics
If the lights do not work, make sure that the lamps are fitted
properly into their housings before you call for technical
assistance.