A)
Signal strength:
The further away the display and camera are positioned from each other, the weaker the signal
is and the fewer bars are displayed. If the camera is out of range, this is clearly indicated on the
screen – the noise level indicator starts flashing and an audible alarm sounds until a connection can
be re-established. A weaker signal can cause the image to occasionally freeze.
B)
Camera number:
Number of the camera currently displayed on the screen.
C)
Zoom:
When the Zoom function is activated, this icon appears and the image is enlarged twofold.
D)
Battery level indicator:
The status of the battery is indicated here. When the battery level falls below 20%, the icon will start flashing and an audible alarm will sound. When charging,
the icon will flash and the status light (13) will light up in red until the battery is fully charged. When this is achieved, it changes colour and turns green.
Always disconnect the mains adapters from the wall power socket before cleaning the unit. Only use a slightly dampened cloth. Do not submerge the unit in water.
Do not use chemical detergents.
This product does not require any special maintenance. Repairs to the unit must be carried out by skilled personnel only.
Problem
No audio or video signal is transmitted
Constant transmission
Constant range alarm
Unclear image or image standstill or sudden black
and white image
Low battery indicated on the display
The display unit speaker does not emit any sound
Range too small
Symbols
Cleaning and maintenance
Troubleshooting:
Possible cause
•
Camera microphone sensitivity is too low
•
No power supply to the camera
•
Camera microphone sensitivity is too high
•
Continuous operation of the screen is activated
without Auto off
•
Camera is turned off or power is not supplied
•
Distance between the units is too large
•
The coupling is faulty or no longer there
•
Range limit reached
•
Brightness at camera location too low, camera
switches to night vision mode
•
Interference from other electronic devices, e.g.
WiFi router, microwave...
•
Built-in battery is empty
•
Continuous operation of the screen is activated
without Auto off
•
The speaker is muted
•
Too much signal interference between camera
and display
5
Action
•
Adjust the sensitivity in the menu
•
Test the power supply
•
Adjust the sensitivity in the menu
•
Set a time limit for continuous operation or activa-
te VOX mode
•
Switch on the camera and test the power supply
•
Reduce distance between units
•
Carry out coupling again
•
Reduce distance between units
•
Adjust the brightness sensitivity in the menu or
increase the brightness at the camera location
•
Increase distance to other electronic devices,
switch off unused devices if possible instead of
switching to stand-by mode
•
Charge the display unit with the supplied charging
cable
•
Set a time limit for continuous operation or activa-
te VOX mode
•
Increase volume using the key
•
Reposition the camera and display