ELECTRICAL PARTS
Delivered with:
• Input Connector: 2 PIN plug.
• Output Cord: 3 cords with Quick Connector.
• Extend Cord: 3 cords with Crocodile Clips + 3 cords with Eyelets
terminals.
ENVIRONMENTAL CHARACTERISTICS
Operating Temperature: 0 to 45°C.
• Storage Temperature: -25 to 85°C.
• Operating Humidity Range: 0 to 90% RH.
• Cooling: Passive / Natural.
TECHNICAL SPECIFICATIONS
Part number
Type
Approvals
Input voltage range
Input frequency
Max output voltage
Charging current
Housing material
Size (LxWxH) in mm
Weight in Kg
Ingress protection
CHARGING INSTRUCTIONS
STEP 1 - Pre charge check & electrolyte level check
• Check the Battery Electrolyte level (Not required on Sealed or Main-
tenance Free Batteries). If necessary, remove the vent caps and
add distilled water so the levels are halfway between the upper and
lower fill lines.
• Check the Voltage Output Switch on the charger and make sure it's
on the correct voltage.
STEP 2 - Connecting the battery charger to your battery
• Select the plug needed (eyelets or alligator clips) and connect it to
the charger.
• Connect the Red lead from the charger to the positive (+) battery
terminal.
FULBAT - www.fulbat.com
Fulbank 2000
Automatic
CE
220-240Vac
50Hz
7.2V±0.3V, 14.4V±0.3V
2A per channel
ABS
202x214x79.5
1.3Kg
IP65
• Connect the Black lead from the charger to the negative (-) battery
terminal.
STEP 3 - Connect the battery charger to mains power (240Vac)
• Connect the battery charger to a 240Vac Mains Powered socket.
• Turn on the 240Vac Mains Power.
• The charger will automatically start when AC power is connected and
switched on. (Note: If the Power Indicator LED flashes in Red, please
check your connections as it's likely that the Positive and Negative
Leads are reversed. Refer to Trouble Shooting Page for further
information, see «LED STATUS INDICATORS TABLE»).
STEP 4 - Disconnecting the battery charger from battery
• Switch OFF and Remove the AC Power Socket from the outlet.
• Remove the Black lead and then the Red lead.
• Check electrolyte levels if possible (As they may need
topping up with distilled water after charging).
THE CHARGING PROCESS
The charging stages are as follows:
Battery check:
• If the battery voltage is more than 7.5V, the charger will charge the
batteries according to 12V mode, the 12V LED LIGHT will turn RED.
• If the battery voltage is less than 7.5V, the charger will charge the
batteries according to 6V mode, the 6V LED LIGHT will turn RED (see
«LED STATUS INDICATORS TABLE»).
• The charger begins charging with 0.8A low current to recover the
batteries automatically if the batteries are not full.
Bulk charge:
• Charges using a constant maximum current (2A) until the battery
reaches 7.2V (6V Batteries) or 14.4V (12V Batteries) - (LED Color- RED).
Maintenance/Pulse:
• Battery is fully charged and is being maintained. (LED Color - GREEN).
3