8 Starting up the outdoor unit
Result: The compressor will heat up and evaporate any
refrigerant in the compressor.
3 Measure the insulation resistance again.
7.2
To finish the outdoor unit
installation
1 Insulate and fix the refrigerant piping and cables as follows:
d
c
a
e
b
f
g
a
Gas pipe
b
Gas pipe insulation
c
Interconnection cable
d
Field wiring (if applicable)
e
Liquid pipe
f
Liquid pipe insulation
g
Finishing tape
2 Install the service cover.
8
Starting up the outdoor unit
See the indoor unit installation manual for configuration and
commissioning of the system.
WARNING
Rotating fan. Before powering ON the outdoor unit, make
sure that the discharge grille covers the fan as protection
against a rotating fan. See
grille" [ 4 11].
Installation manual
16
"4.2.4 To install the discharge
ERLA11~16DAV3+W1
Daikin Altherma 3 R
4P643598-1 – 2021.09