For guidance with regard to electrical connections, refer
to the installation manual.
Hydraulic connections
(optional)
only "mood M/L/XL" with bio sauna
If the model is equipped with an automatic filling tank a 1/2"
M (cold water) fitting must be provided) (position 5 .
In order to ensure correct operation, the pressure and flow
rate values must also comply with the values specified in the rel-
evant "Hydraulic specifications".
Where "hard" water is present, it is advisable to install
a decalcifier in the water system supplying water to the
appliance, in order to reduce and/or avoid calcareous
deposits.
ATTENTION: (IEC 60335-1) The pressure of the water
system supplying water to the appliance must not ex-
ceed 600 kPa (6 bar).
Alarm button set-up (optional)
The equipment can be fit with a button to be connected to an
alarm circuit: provide, in the area marked with the bell symbol, a
bipolar cable with characteristics not inferior to type H 05 VV-F,
and that is long enough to connect to the button (located inside
the sauna near the heater).
The cross-section of the cable must be sized based on the en-
ergy consumption of the bell/alarm or other that you want to use.

Audio system set-up (optional)

The equipment can be fit with speakers* that are connected
to a cable ratio system; to do so, the specific cable must be pre-
pared as shown in position 3/3a; it will be connected with the
cable coming from the equipment during the installation phase.
NOTE:
(*) two non-amplified speakers, impedance: 8 Ω - nominal power:
10 W x 2.

Electrical safety

Mood is a safe appliance, manufactured according to EN 60335-
1, EN 60335-2-53 regulations and tested during production to
guarantee user safety.
Installation must be carried out by qualified and authorized
personnel, in compliance with the national provisions in force.
It is the installer's responsibility to select the materi-
als, considering the way they will be used; to carry out
the installation correctly; and to verify the condition
of the network to which the system will be connected
and its capability to ensure safety in maintenance
and inspection operations.
Class "1" appliances must be immutably connected, without
intermediate junctions, to the electrical mains and protection
circuit (ground system).
The building's electrical system and ground system
must be efficient and must conform to legal regula-
tions and specific national standards.
Where required, appropriate devices must be provid-
ed, which form part of the fixed system, and installed
in compliance with current legislation in force, with
the purpose of disconnecting the appliance from the
mains (see also "Electrical connections arrangement").
For connection to the electric mains, you will need to install
one or more isolating multi-pole switches, which will ensure
complete disconnection in the instance of a category III over
voltage; these devices must be connected to an area that com-
plies with the safety regulations governing bathroom safety.
Switches and electrical devices, according to regula-
tions, must be connected to areas out of the user's reach.
The installation of electrical devices and equipment (sockets,
switches, etc.) in the bathroom must be in compliance with legal
standards and regulations in the country where the appliance is in-
stalled.
In the case where the building's electrical system is not
able to provide a constant power supply, we recom-
mend installing a voltage regulator, suitable to provide
the required power, before installing the appliance.
The building's electrical system must be equipped
with a 0.03 A differential switch.
The appliance is equipped with a LED lighting system in com-
pliance with Norm EN 62471, lamp classification group: exempt.
Do not look directly at the light using optical devices (bin-
oculars, cameras, magnifying glasses).
Do not connect other lighting systems.