Reliable BRIO PRO 1000CC Manual De Instrucciones página 9

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Note: The steam volume being used may be regulated from a dial on the hose handle - See
the following Features section on HOW TO CHANGE STEAM VOLUME.
HANDLE CONTROL
5.
When the water level is low in the water tank, a red low water light (B) will light up.
Remove the tank cap (4) and refill the water tank at this time.
6.
When finished use, turn the main power switch (1) back to position O, and unplug from
wall. Please allow the unit to cool down prior to storage. If not using the unit for an
extended period of time (more than 3 months), it is advised to drain the steam generator
tank.
To drain the steam generator tank:
Drain the tank only when the unit is cold. Make sure unit is unplugged from wall and the hose
is not connected to the unit. Carefully turn unit upside down so that the bottom is facing
upwards. Unscrew the drainage cap at the bottom of the machine, then open the boiler drain-
age plug using the 20mm hexagonal drain nut opener (provided with the accessory kit (19)).
Once the tank is open, carefully turn the machine around and empty steam generator tank.
Once emptied, replace the drain nut and cap.
Note: Do not store unit where the temperatures may fall below freezing. Water freezing
inside the unit may cause damage to components.
HOW TO CHANGE STEAM VOLUME
1.
The steam volume can be controlled by the steam regulator knob located on the steam
hose handle.
Positions 1 to 3 are for steam only. Each successive number provides a higher volume than
the last. (1. Low. 2. Medium. 3. High.)
Position 4 activates the hot water injection function. This feature mixes steam and hot water
to produce a strong cleaning jet. **Please note in this position, the steam pressure and water
level will go down much more quickly than if steam only is being used.
THIS MODEL IS PROVIDED WITH THE
FOLLOWING FEATURES
STEAM READY LIGHT (A)
A green light signals that the steam has reached the maximum working pressure and the unit
is ready to be used.
LOW WATER CONTROL LIGHT (B)
A red low water warning light signals that the water tank needs to be refilled. If you wish to
continue steam cleaning, unscrew the water tank cap (4) and refill the tank.
06

Publicidad

Tabla de contenido

Solución de problemas

loading

Tabla de contenido