User and installation manual HNS-M2

Electrical connections

The sauna heater must be connected to the mains by a qualified electrician and in compliance with current
regulations. The steam generator is connected with a semi-permanent connection. Use H07RN-F (60245 IEC 66)
or a corresponding type cables
Output
Steam generator
connection cable
H07RN-F / 60245
IEC 66
kW
400V-415V 3N~
3.4
5 x 1.5
4.7
5 x 1.5
6.0
5 x 1.5
7.7
5 x 2.5
9.5
5 x 2.5
12.0
14.0

Main switch

There is a main switch at the bottom of one end of the steam generator, which is used only when the steam room is
not to be used for a long period of time.
The steam generator's automatic flushing and rinsing function will stop, if the power is switched off.
(Optional, Automatic drain valve)
Teho
Power
Leistung
3.0
3.4
4.7
6
7.7
9.5
12
14
Fuse
Steam generator
connection cable
H07RN-F / 60245
2
mm
A
3 x 10
3 x 10
3 x 10
3 x 16
3 x 16
5 x 6
3 x 25
5 x 6
3 x 25
Steam generator's heating elements
Vastus / Element / Heizstäbe 230V
1
1000W/SEPD 131
1000W/SEPD 130
1150W/SEPD 97
1150W/SEPD 111
1567W/SEPD 98
1567W/SEPD 112
2000W/SEPD 99
2000W/SEPD 113
2567W/SEPD 100
2567W/SEPD 114
5250W/SEPD 116
3500W/SEPD 115
4250W/SEPD 119
3500W/SEPD 115
5250W/SEPD 116
3500W/SEPD 115
Fuse
Steam generator
connection cable
IEC 66
2
mm
230V 3~
A
230V-240V 1N~/2~
4 x 1.5
3 x 10
4 x 2.5
3 x 16
4 x 2.5
3 x 16
4 x 6
3 x 25
4 x 6
3 x 25
4 x 10
3 x 35
4 x 10
3 x 50
2
3
1000W/SEPD 131
1150W/SEPD 97
1567W/SEPD 98
2000W/SEPD 99
2567W/SEPD 100
5250W/SEPD 116
4250W/SEPD 119
5250W/SEPD 116
Fuse
H07RN-F /
60245 IEC 66
2
mm
A
3 x 2.5
16
3 x 6.0
25
3 x 6.0
25
3 x 10
35
------
------
------
------
------
------
7
Room
size
*)
3
m
1,5 – 2,5
2,5 – 5
5 – 7
7 – 10
10 – 12
12 – 15
15 - 18