Page 8
area.
If the barrier body is exposed to passing vehicles, install, if possible,
adequate means of protection against accidental impacts.
upright.
3.2. MASONRY FOR FOUNDATION PLATE
Plinth dimensions must be adequate for the type of installation
and soil.
sheaths for routing electrical cables.
The rounded part of the foundation plate must face the internal
part of the passage to be automated.
Using a spirit level, check if the plate is perfectly level.
Wait for the cement to set.

3.3. MECHANICAL INSTALLATION

Remove the 4 upper nuts from the foundation plate.
Remove both screws securing the upper cover, see Fig.7, ref.
Fit the release key into the lock of the cover, Fig. 8, and turn it clockwise
until it stops.
Keepi ng the k ey in this position, r emove the upper cover,
Fig. 8.
Prepare the automated system for manual operation, see paragraph
7
Place the spring rod, Fig. 11 ref.
direction:
If the rod closes to the left of the upright, right hand installation,
the plate must be secured on pin
If the rod closes to the right of the upright, left hand installation,
the plate must be secured on pin
installation type (right hand or left hand).
Place the rod plate in the front part of the automated system keeping
it horizontally, Fig. 14.
For the RAINBOW 724 C model, pay attention to the orientation
of the holes indicated in Fig. 14 ref.
plate top part.
Secure the rod plate using relevant screw, lock washer and washer,
Fig.15.
3.4. ASSEMBLING THE ROD
To assemble the rod, you should remember that:
The rubber edge, with the rod in closing position, must face the
ground.
The hole on the rod must be coupled with the pin coming out of the
driving plate.
Place the cheek plastic Fig. 16 ref.
Place t he rod on the central pi n with the rubber edge faced
downward.
screws.
correspondence with the holes on the rod plate.
automated system and installation (left hand or right hand).
3.5. INSTALLING AND ADJUSTING THE BALANCING
SPRING
To operate correctly, the automated system must be equipped with one
or two balancing springs that must be ordered separately according
to the automated system model, to the rod type and to any selected
accessories.
To install and adjust the spring, follow the instructions below:
Move the beam into vertical position and prepare the automated
system for normal operation, see paragraph 8. Make sure that the
rod cannot be moved by hand.
19.
.
, horizontally.
: the holes must be on the
, as shown.
, and secure it using the supplied
, in
and
on the other end of the spring; secure the whole part in the hole
Prepare the automated system for manual operation adjusting the
release device as shown in paragraph 7.
By means of the bottom nut, Fig. 20 ref.
spring.
The spring is correctly tensioned when, after having positioned
the rod to 45°, it stands still.
7. After you have adjusted the spring, block the tie-rod position tightening
3.6. ADJUSTING THE MECHANICAL STOPS
Two mechanical stops are provided on the upper part of the upright, Fig.
21 ref.
and
.
To adjust the position of the stops, operate as follows:
Manually move the rod into closing position.
Using the screw, move the rod into horizontal position.
Move the rod into vertical position and do the same for the other
mechanical stop.
We recommend you to grease both mechanical stops periodical-
ly.
3.7. ADJUSTING THE TRAVEL LIMIT DEVICES
Two travel limit devices are located on the automated system to identify
the rod position, open or closed, Fig. 22.
The automated system is supplied with travel limit devices
already prepared for a left hand installation of the beam.
To adjust the cam position, operate as follows:
Manually move the rod into closing position.
, until the travel limit device engages.
Slightly advance the cam.
The travel limit device must operate before the mechanical
stop.
Block the cam position tightening the relevant screw.
Move the rod into opening position.
, until the travel limit device engages.
Slightly advance the cam.
The travel limit device must operate before the mechanical
stop.
Block the cam position tightening the relevant screw.
In the event of right hand installations, reverse the wires of the
travel limit devices connected to the unit, see control board
instructions.
Block the automated system again as indicated in paragraph 8.
4. INSTALLING THE ACCESSORIES (Optional)
Holes have been prepared on the upright of the automated system to
facilitate fastening operations for accessories (if any), such as photocells
(Orion) and key-selector (Quick).
automated system.
On the upright sides as well as over the entire beam length you can
install signalling lights.

5. ELECTRIC CONNECTIONS

Install an omnipolar switch on the power supply mains of the
automated system with contact opening distance of 3 mm or
more. The use of a thermal magnetic switch 6A with omnipolar
switching is recommended.
upstream of the system.
At the end of the assembling and adjusting operations of the mechanical
part of the automated system you can connect the power mains and all
To connect the power cable you need to open the prepared hole on
M16x1.5.
A channel for the cable routing has been prepared inside the
upright.
The power cable must enter the control unit passing through its
dedicated cable gland.
To connect the power line and the accessory line to the control
.
, to eliminate any spring clearance.
, start to tension the
.
.
, and mount the supplied cable gland

Publicidad