Do not place the electric fence in mires, marsh areas or places where the animal cannot
retreat.
Avoid placing the fence near areas where there is a risk of explosion, inflammable liquids,
etc. as small sparks from the fence links may provoke a fire.
In the case of storms it is advisable to disconnect the fence from the electric fencer and
from the electrical current.
We recommend placing signs to indicate the location of the electric fence.
Finally connect the electric fencer to the mains. If everything is in order, the equipment
should produce periodic electrical discharges.
With respect to battery-powered electric fencer, connect the red cable to the positive termi-
nal and the black cable to the negative battery terminal. Make sure a proper battery is
being used and it is completely charged.
For each discharge the pilot light up (Fig.1), if this does not occur it means that the fence is
losing charge through a grounded connection, disconnect the electric fencer from the elec-
trical power supply and check the fence.
For ECB-12 models, enusre that the terminal areas are free from branches, plants, etc. in
order to avoid discharges trough accidental contact.
POSSIBLE ANOMALIES AND SOLUTIONS
ANOMALY
The electric fencer
does not produce a
discharge
Pilot light failure
EXPLODED DIAGRAMS
ECB-12 V
Nº
Description
1
Potentiometer
2
Negative terminal
3
Positive terminal
4
Condenser
5
Control circuit
6
High voltage transformer
7
On indicator
8
Low battery indicator
9
Fence fault indicator
SOLTER
SOLDADURA S.L.
POSSIBLE CAUSE
Check that the electric fencer is connected to the electrical power
supply and that the supply voltage is correct.
For battery-powered fencer ensure that the battery is charged and
that the terminals are connected properly.
With the electric fencer off, disconnect the fence cables and recon-
nect the electric fencer. If the pilot light no lights up on each dis-
charge, the problem is to be found in the fence. Check the insulation
in the entire fence, dividing it if necessary.
Check that there is power on the output terminals, use an insulated
screwdriver to touch a terminal and move it half a centimeter from
the other terminal, if everything is in the correct position, discharges
should happen every second.
Code
73102
89304
89303
89103
89100
-
77500
77500
77500
2