Taking Into Operation - EHEIM thermocontrol Serie Manual Del Usuario

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 25
before removing it from the water and let it
cool down in the water • After removing the
heater put it on a non-flammable, heat resi-
stant surface (no paper, cloth etc.)
Risk of overheating: Water level must never be
below minimum mark c on the housing. Max.
immersion depth 0.5 m.
Do not operate the heater with an additional
clock timer or an additional control system.
When disposing of the appliance, heed the
respective statutory regulations. Information
on the disposal of electrical and electronic
appliances in the European Union: Within the
European Union, disposal of electrically ope-
rated appliances is governed by national regu-
lations that are based on the EU Directive
2012/19/EU on waste electrical and electronic
equipment (WEEE). The appliance may no lon-
ger be disposed of with the municipal or hou-
sehold waste. The appliance will be accepted
free of charge at municipal collection points or
recycling centres. The product packaging is
made up of recyclable materials. Dispose of
them in an environmentally responsible man-
ner and take them for recycling.
Thermostatic aquarium heater
A a Temperature selector ring (blue) b Indicator ar-
row (red) c Minimum water level mark d 2 suc-
tion cups e Double suction cup holder f Con-
trol light g Mains cable h Drip loop I Trans-
port securing device.
• Before you start, set the heater in the aquarium
water for 20-30 minutes without plugging it.
• Check device for damage • Remove transit pro-
tection I • Fix suction cups d to double suc-
tion cup holder e and clip onto heater (not insi-
de the heating zone and close to the indicator
lamp) • Mount thermostatic heater with double
suction cup holder e vertically in the aquarium, fixing it
in a place where water flow is brisk (filter outlets/ vents)
• Set temperature • Plug into mains socket. Attention: Do
not use the heater in the aquarium unless it is secured
in position. Check that drip loop h is in position!
B Disconnect the power plug. Turn the temperature sel-
ector ring a to the desired temperature. Insert the
power plug. "Red light" f = heater in operation
If, after a day or two in operation the setting scale does
not correspond to the water temperature, follow the
following procedure to recalibrate the heater:
• Switch off the heater and unplug it from the mains
supply • Measure the water temperature with an ac-
curate thermometer • Turn indicator arrow (red) b to
point to the measured temperature • Set the desired
tank temperature with the temperature selector ring
(blue) a . • Insert the power plug.
Function

Taking into operation

Setting temperature
Recalibration

Hide quick links:

Publicidad

Tabla de contenido
loading

Tabla de contenido