EN
1.7 Meter technical specifications
Features
Sensor
Compatible meters
Sensor resolution
Alarms
Configuration
Power supply
Battery lifespan
Certifications/Approvals
Operating frequency
Radiated power
Reference standards
Radio equipment class
Radio
Environmental conditions
Protection rating
Depends on the meter model to which it is connected.
Tampering, electronic fraud, backflow, presumed leak, maxi-
CE in compliance with European standards.
Standard
Modes
range
Range
Frame Tiny (default): current volume, date and time, volume
Short frame: current volume, volume on billing dates, meter
Data sent
Long frame: same as short frame with addition of values for
Frame Arrow: current volume, volume on billing date, meter
Description
Inductive (two-way)
MVM, MVM PlusC, WMAP Evo
mum flow, inverted meter
Via radio using configuration kit
Lithium-ion battery
15 years + 1 in storage
RED 2014/53/EU, RoHS2 (EU) 2017/2102
ISO 4064 Ancillary device 6.3
OMS:
Wireless M-Bus, OMS
C1 (Default), T1 (Optional)
868.0 - 868.6 / 868.7 - 869.2 MHz
max 14dBm
500 m in line of sight
EN 13757
Class 1
on billing date, billing date, errors.
serial number, alarms.
the previous 12 months
serial number, billing date, alarms
Storage temperature: -20°C – +60°C
Operating temperature: -10 °C – +55 °C
IP68
17