5.3.3 Personal safety equipment
a) The user and any other persons in the vicinity must
wear suitable eye protection, a hard hat, ear pro-
tection, protective gloves, safety footwear and
breathing protection while the machine is in use.
6. Before use
Ensure that the tool is not yet connected to the electric
supply.
6.1 Fitting the side handle
1. Position the side handle on the tool.
2. Secure the side handle by tightening the screw knob.
6.2 Use of extension cords
Use only extension cords of a type approved for the
application and with conductors of adequate cross sec-
tion.
Recommended minimum conductor cross section and
max. cable lengths:
Mains voltage
Conductor cross section
1.5 mm
2
2.0 mm
100 V
–
20 m
110–120 V
20 m
25 m
220–240 V
50 m
–
Do not use extension cords with 1.25 mm
conductor cross sections.
7. Operation
7.1 Preparation for operation
7.1.1 Adjusting the position of the side handle
1. Unplug the supply cord form the power source.
2. Release the screw knob on the side handle.
3. Bring the side handle into the desired position.
4. Secure the side handle in the desired position by tight-
ening the screw knob.
7.1.2 Fitting the insert tool
1. Unplug the supply cord form the power source.
2. Check that the connection end of the insert tool is
clean and lightly greased. Clean it and grease it if
necessary.
3. Check that the sealing lip of the dust shield is clean
and in good condition. Clean the dust shield if nec-
essary or replace it if the sealing lip is damaged. (See
Printed: 07.07.2013 | Doc-Nr: PUB / 5071189 / 000 / 00
AWG
2
2.5 mm
2
3.5 mm
2
14
12
–
30 m
–
–
30 m
–
75 ft
125 ft
100 m
–
–
–
2
or 16 AWG
Wear a
Wear eye
hard hat
protection
breathing
protection
Wear safety
boots
6.3 Use of a generator or transformer
This tool may be powered by a generator or transformer
which fulfils the following conditions:
– AC voltage output, power output at least 2600 W.
– The operating voltage must be within +5 % and –
15 % of the rated voltage at all times.
– Frequency range 50–60 Hz, never above 65 Hz.
– Automatic voltage regulation with starting boost.
Never operate other tools or appliances from the gen-
erator or transformer at the same time. Switching other
tools or appliances on and off can cause undervoltage
and/or overvoltage peaks which may cause damage to
the power tool.
section 8.)
4. Push the insert tool into the chuck and rotate it while
applying slight pressure until it engages in the guide
grooves.
5. Push the insert tool further into the chuck until it is
heard to engage.
6. Check that the insert tool has engaged correctly by
pulling on it.
7.1.2.1 Positioning the insert tool
7. Turn the chisel adjustment and locking switch to the
"Rotate chisel" position.
8. Rotate the chisel to the desired position.
7.1.2.2 Locking the insert tool
9. Turn the chisel adjustment and locking switch to the
"Lock chisel" position.
Wear
Wear ear
Wear
protection
protective
gloves
en
5