3 609 929 721/1.2 | KE300
5 Initial Operation
5.5
Interface X 13: RS232/RS422
The interface X 13 is intended for connecting
data collection terminals, bar code readers,
etc.
Functionality depends on the present func-
tional scope of the firmware. This is de-
scribed in the system handbook.
The 25pin plug provides the connections for
an RS232 or RS422 interface. It is only pos-
sible to use one of these interfaces. Determi-
nation of the used interface arises from the
wiring of the pinned-up plug.
13
25
Fig. 10: SUB-D-plug,
25pin (male)
Pin
Signal
Description/Function
1
NC
2
TxD
RS232 Send
3
RxD
RS232 Receive
4
RTS
RS232 Request Send
5
CTS
RS232 Enable Send
6
NC
Not Connected
7
ISO_GND Reference Potential Interface
8
NC
Not Connected
9
-
-
10
-
-
11
RxD_A
RS422 Receive +
12
-
-
13
-
-
14
RxD_B
RS422 Receive –
15
NC
Not Connected
16
NC
Not Connected
17
NC
Not Connected
18
TxD_Z
RS422 Send +
19
TxD_Y
RS422 Send –
20
DTR
RS232 Data Terminal Ready
21
NC
Not Connected
22
-
-
23
-
-
24
ISO_GND Reference Potential Interface
25
ISO_GND Reference Potential Interface
RS422
Table 6:
Electric Drives and Controls | Bosch Rexroth AG 17/52
1
14
5.5.1
Circuit Diagram Examples for
the use of RS 422
Receiver
KE300
+ 5 V
1 kΩ
RxD_B
RxD_A
1 kΩ
Fig. 11:
Sender
KE300
TxD_Z
18
19
TxD_Y
only when
needed
7, 24, 25
Fig. 12:
Sender
14
330 Ω
11
only when
needed
7, 24, 25
Receiver
min.
120 Ω

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

0 608 830 162

Tabla de contenido