Descargar Imprimir esta página

STAR Water Systems DL 2092 Guia De Inicio Rapido

Programando la valvula de control

Publicidad

Idiomas disponibles

Idiomas disponibles

Enlaces rápidos

PROGRAMMING THE 2092 "DR" CONTROL VALVE
WARNING: ALWAYS TURN INDEXING KNOB
CLOCKWISE. OTHERWISE, DAMAGE TO THE
VALVE MAY RESULT AND VOID WARRANTY.
A. SET CURRENT TIME OF DAY
1) Plug unit into a 115 volt grounded outlet that is
independent from a wall switch or pull chain.
2) Set present time of day by depressing and holding
in black button on left side of indexing knob (Figure
A). Turn the large hour gear until the actual time of
day is opposite the time of day pointer, noting AM
and PM marking. The regeneration cycle is factory
set to occur at 2 AM.
If a different regeneration time is desired, set the time of
day on the large hour gear ahead or behind the actual
time of day to compensate.
3) Release the black button, making sure the large
hour gear is engaged.
B. SET HARDNESS LEVEL OF THE WATER
Based upon the average national water hardness level,
the valve has been factory pre-set. However, water
hardness will vary by location. For best efficiency, the
valve should be programmed to each specific installation.
If the water source to be treated is city water, call the
water department for the water hardness level. If the water
source is a private well; information concerning the mineral
content (Hardness) can be obtained by purchasing the
136958 mail-in test kit from your dealer. Return a sample
of untreated water in the bottle provided with the kit to
our laboratory. The water sample will be professionally
analyzed and the results of the analysis will be mailed to
you.
1) To program the water hardness level, locate the
stick people wheel (Figure B.)
2) With your thumb and forefinger, grasp the stick
people wheel. Pull the wheel outward and turn until
the number of people in your family matches the
water hardness level.
C. GENERAL INFORMATION
1) Once you have set the people and hardness, this
will automatically set the "White Dot" on the number
of gallons (hundreds of gallons) available as soft
water before the unit needs to regenerate.
2) As you use water in your home, the "White Dot" will
move to the left (counter-clockwise) and subtract
gallons from the available soft water gallons. This is
indicated by reading the "Blue Arrow". This
Indexing knob
Black button
METER
IN SERV.
TO SET TIME OF DAY-PRESS BLACK
BUTTON AND TURN LARGE GEAR UNTIL
PRESENT TIME APPEARS ABOVE ARROW.
FOR MANUAL REGENERATION TURN KNOB
CLOCKWISE TO REGEN. POSITION.
Time of day pointer
FIGURE A
Water
hardness
wheel
FIGURE B
Trip arm
Stick people
wheel
Water
hardness
wheel
FIGURE C
1
Large hour gear
Blue arrow
CAPACITY (GALLONS)
2a
TIME
OF DAY
Stick people wheel
IL0410
Gallons remaining
until next regeneration
"Blue arrow"
Gallon
wheel
Available gallons of soft
water "White dot"
FW1738 A
IL0411
IL0409

Publicidad

loading

Resumen de contenidos para STAR Water Systems DL 2092

  • Página 1 PROGRAMMING THE 2092 “DR” CONTROL VALVE Large hour gear WARNING: ALWAYS TURN INDEXING KNOB CLOCKWISE. OTHERWISE, DAMAGE TO THE Indexing knob Black button Blue arrow VALVE MAY RESULT AND VOID WARRANTY. CAPACITY (GALLONS) METER A. SET CURRENT TIME OF DAY 1) Plug unit into a 115 volt grounded outlet that is IN SERV.
  • Página 2: Flow Meter

    indicates how many gallons of soft water remain before a DIAL READING CYCLE TIME regeneration will take place. NOTE: FOR WATER WITH RUST STAINS: 1. In Service 2. Regeneration If iron is present in the water supply as evidenced by red 3.
  • Página 3: Ajuste El Nivel De Dureza Del Agua

    PROGRAMANDO LA VÁLVULA DE CONTROL 2092 “DL” ¡AVISO! SIEMPRE GIRE EL BOTÓN INDICADOR EN Engranaje grande de 24 horas EL SENTIDO DE ROTACIÓN DE LAS MANECILLAS Botón indicador DEL RELOJ. DE OTRA MANERA, DAÑOS A LA Botón negro Flecha azul VÁLVULA PUEDEN RESULTAR EN INVALIDAR LA GARANTÍA.
  • Página 4: El Ciclo De Regeneración

    el sentido de rotación de las manecillas del reloj de agua blanda disponibles, lo cual se determina empezando con “Resaca” (Backwash), y pasando por mediante lectura de la “flecha azul”. Así se indica “Deslavado de Salmuera” (Brine Rinse), y “Relleno de cuántos galones de agua blanda quedan antes de Salmuera”...
  • Página 5 PROGRAMMATION DE LA SOUPAPE RÉGULATRICE 2092“DR” Grande roue dentée pour les heures Button de reglage AVERTISSEMENT: TOURNEZ TOUJOURS LE Button noir Flèche bleu BOUTON DE RÉGLAGE DANS LE SENS HORAIRE. SINON, CECI POURRAIT ENDOMMAGER LA CAPACITY (GALLONS) METER SOUPAPE ET ANNULER LA GARANTIE. A.
  • Página 6: Mise En Marche De L'APpareil

    3) La soupape régulatrice mesurera l’écoulement de l’eau 2. À mesure que l’eau est utilisée, le « Point blanc » se et une régénération se produira seulement après qu’une déplace vers la gauche (dans le sens inverse des aiguilles d’une montre) et soustrait les gallons de la quantité d’eau quantité...