Troubleshooting

The drawers can always be opened manually like conventional drawers, even when isolated.
It is often helpful to disconnect the system from the mains. Wait 10 seconds before switching the
system on again.
Fault
Cause
The drawer does
The spring-loaded front buffer facilitating the
not open - neit-
activation path
her by pulling
 is missing or defective.
nor by pushing
Drawer is blocked, e.g. by stowed items.
The drawer back is bent to the rear.
The opening unit is temporarily or perma-
nently de-energised or defective.
Â
✓ Green: Power supply OK
a) Flashing in red:
Opening unit is temporarily out of order
b) Red: Opening unit is defective
c) No indication: Power supply is interrupted
or opening unit is defective
Cross beam cable is not mounted correctly.
The operation indicator on the power supply
unit is lit.
The operation
The power cable is not correctly connected
indicator on the
to the power supply unit or defective.
power supply
There is no voltage present at the power
unit is not lit.
socket used.
The power supply unit is defective.
When the drawer
Rack is not aligned horizontally.
is opened it
Switch for the opening force is not set cor-
slides against
rectly.
the end stop too
quickly.
Drawer does
Rack is not aligned horizontally.
not open wide
Switch for the opening force is not set cor-
enough.
rectly.
Opening unit is defective.
The drawers of
Connection cable is not plugged in or is
the entire cabinet
defective
do not open
30
Check the LED
Remedy
 Fit the spring-loaded front buffer.Front
height up to 300 mm: 1 per side, front
height > 300 mm: 2 per side
 Replace the spring-loaded front buffer
 Remove the blocking item
 Straighten the back of the drawer
 a) Wait 3 min
 b) Switch the system on and off or
replace the opening unit (see chapter
8.0)
 c) Slightly shift the opening unit and
mount it again, or replace it (see chap-
ter 8.0)
 Check that the frame cable is correctly
fitted into the cross beam and make
any necessary corrections
 Check that the power cable is seated
firmly, or replace it
 Switch on the switchable power socket
 Use another power socket
 Check the fuses
 Replace the power supply unit
 Align the rack
 Shift the switch to the left (see chapter
10.0)
 Align the rack
 Shift the switch to the right (see chap-
ter 10.0)
 Replace the opening unit (see chapter
8.0)
 Check that the power cable is seated
firmly, or have it replaced by an autho-
rised expert
Translation of the original operating instructions