The central unit stops by itself without the user's desire to do so.
- Ensure that all the vacuum inlets and the skirting board dust pan are closed, then carry out
a duct network test by pressing the "Test" button on the central unit for 3 seconds.
• Green indicator light = vacuum cleaning network OK
• Orange indicator light = network OK, low leakages detected
• Red indicator light = leak => Check the network, then re-run a test
- Start the centralised vacuum cleaning unit.
The central unit stops
- Disconnect the central unit
from the network
- Start the central unit
The central unit
does not stop
There are blockages in the ductwork or in the
accessories
- Check that the handle and the hose are not
blocked off
- Check that the ductwork is not blocked off (carry
out tests by connecting up to several different
network vacuum inlets)
The central unit stops
16
The central unit operates correctly.
Incident inside the central unit
- Check that the filter bag is
not full
- Check the electrical connections
- Check that there is no 'plug' or
blockage in the central unit