EN
EN
SYSTEM INTERFACE
SETTING THE INPUT TYPE
"status" LED will stay lit, indicating which channel is selected. The selected channel will change automatically
each second, increasing from CH1 to CH4 and then back to CH1. Once the LED indicator for the channel that you
want to edit is lit, press the "STOP" button.
3.
Once the desired channel has been selected, the LED indicator for that channel will start to blink. The blinking
speed will determine the input type:
- Fast blinking: channel is N.C. (normally closed).
- Slow blinking: channel is N.O. (normally open).
A short press on the "STOP" button changes between N.O. and N.C.. Once you have
type, press and keep pressed "STOP" until the LED indicator stays solid "on" . At this point, after releasing the
"STOP" button the system will go back to the channel selection step, where you can select and edit another
channel.
4.
Once you have modified all the required channels, put the bypass key back to "normal" mode to save the changes
and put back the unit into normal working mode.
SYSTEM INTERFACE
This unit is factory equipped with an internal acoustic alarm ("buzzer"). This alarm will turn on each time an input is
triggered, and will stay on until the "STOP" button is pressed. Additionally, an external alarm can be connected to the
system; this external alarm (visual and/or acoustic) will behave exactly as the internal one previously explained.
10
SB 3050 R. 06/20
Balcrank Corporation - Weaverville - NC · Tel.: 800-747-5300 · www.balcrank.com
selected the proper input