INSTALLATION AND COMISSIONING
ELECTRICAL WIRING
Solenoid outputs
As the unit has four channels with four inputs, four
outputs are available. Outputs are intended to control
24Vdc solenoid valves, although relays or other control
devices can also be controlled. Connect both wires of the
External alarm output
This single output is intended to control an external
(remote) 24Vdc flash indicator and/or warning buzzer.
When one or more inputs are triggered, this output
Balcrank Corporation - Weaverville - NC · Tel.: 800-747-5300 · www.balcrank.com
solenoid to the desired channel connector (for solenoid
valves, don't care about polarity; for other devices, respect
the indicated polarity).
becomes active. Connect both wires of the external alarm
to the external alarm connector (respect the indicated
polarity).
External alarm
connector
Output connector
(1 to 4)
5
R. 06/20 SB 3050
EN
EN