FAULT
not cool enough.
The products
are warm.
The ICM
sometimes
makes noise.
There is water
on the floor.
The lights don't
work.
If after all the above-mentioned checks the problem with your ICM remains, contact the customer
service department of your supplier and provide the following information:
•
Type of ICM
•
Serial number of the ICM
•
Brief description of the problem / observation
11. First aid
In case of accident, it is recommended:
ACCIDENT
Inhalation of refrigerant
Contact with eyes
Contact with skin
POSSIBLE REASONS
The ICM has recently been reloaded with
warm products. It takes 8-16 hours to
cool them down.
The ICM is loaded in such a way that the
air circulation in the interior is getting
blocked.
The door does not seal properly.
Leakage in the cooling system.
For this particular ice cold
merchandiser, a powerful mechanism is
needed and consequently a certain
amount of noise cannot be avoided.
Intense metallic noise.
Inclined or curved floor.
The drainage hole for the condensate
water is blocked.
There is a leakage in the tray.
The fluorescent tubes or ballast or starter
are out of order.
IMMEDIATE ACTION
Take deep breaths of clean air. If irritation persists, contact a
doctor.
Wash your eyes thoroughly with plenty of water for at least 15 minutes
and then consult a doctor.
Wash immediately with water.
HANDLING
Preferably, reload the ICM before night
closing.
Load the ICM according to the
standards you have been provided
with by the company.
Repair the doors for proper closing
(this type of repair should be
performed by an authorized
technician).
Repair the leakage (this type of repair
should be performed by an authorized
technician).
Ice Cold Merchandisers are of
dynamic type, according to the
specifications that the company is
offering.
Call a service technician.
Level the ICM properly by adjusting its
feet. Placing a spirit level on the top of
the ICM will assist you in leveling it.
Unblock the drainage hole.
Call a service technician.
Call a service technician.
ENG
18