2. Open the plug  (turn anti-clockwise) and dispense
liquid.
3. Close the plug  (turn clockwise).
4. Turn the angle discharge  up after dispensing to
prevent dripping. If necessary, loose the union nut
, before turning up.
WARNING!
Bodily injury due to escaping liquid
`
`
Close the stopcock completely after dispensing
(set plug to at least „zero").
`
`
Keep the stopcock closed when it is not in use.
Accessories
Type
Antistatic set
Compact jerrycan, electroconductive
Compact jerrycan, electroconductive
More accessories can be found at www.buerkle.de
Annex
Operational directive in accordance with 1999/92/EC:
Zone 0
Zone 1
Zone 2
Product directive in accordance with 94/9/EC:
Group I
Group II
Group IIA
Group IIB
Group IIC
Specification
to prevent electrostatic charging
5 l, with threaded connector 3/4"
10 l, with threaded connector 3/4"
a potentially explosive atmosphere is assumed to be continuously present
a potentially explosive atmosphere is assumed to be occasionally present
a potentially explosive atmosphere is not anticipated (and if it does occur, then only
rarely and briefly)
for use in mining
for use in other areas subject to explosion hazard
Maximum permitted gap > 0.9 mm
0.5 mm < maximum permitted gap < 0.9 mm
Maximum permitted gap < 0.5 mm
Troubleshooting
Problem
To eliminate the error
Thread
1. Thread is damaged (contact dealer
connection
or manufacturer).
is not sealed
Stopcock is
1. Close the plug more tightly.
dripping
2. Turn the discharge so it is pointing up.
English
Num-
Item No.
ber
1
5602-1000
1
0435-2055
1
0435-2105

Publicidad

loading

Este manual también es adecuado para:

0525-1100