Safety Instructions; Replacing The Batteries - SOMFY 9015179 Manual Del Usuario

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 8
BATTERY REPLACEMENT - GDO SOLAR/BATTERY KIT
Refer to the Solarset manual when replacing the SOLARSET's batteries.

Safety instructions

The safety instructions are to be observed during any installation operation.
Do not connect to the solar panel or the motor before finishing the installation process.
Under no circumstances use a high-pressure water cleaner.
When installing the battery cases, wear protective glasses and clothing, and use only insulated tools. If connecting and disconnecting storage
batteries, observe the procedures defined by UTE C 18-510 (wear a face shield). Observe the accident prevention rules, as well as standards
EN 50272-2 and EN 50110-1.
Any acid splashes on the skin or eyes must be immediately washed with plenty of clean water. Seek medical help immediately. Wash clothing
in water.
The electrolyte is highly corrosive. Under normal operating conditions, direct contact with the electrolyte is impossible. If the monobloc is
damaged, do not touch the electrolyte.
The batteries do not require servicing or topping up with water. Whenever a battery is opened it will be destroyed and its warranty
invalidated.
Keep the batteries out of the reach of children.
Do not throw out your device or spent batteries with domestic waste. It is your responsibility to dispose of your electronic equipment in the
relevant recycling points.

Replacing the batteries

The metal parts of the batteries are still live: do not place parts or tools on the batteries!
Always replace both batteries at the same time.
[1]. Gently remove the adhesive protectors from the
terminals so that they can be affixed to the new
batteries.
[2]. Disconnect in the following order:
- the motor (A)
- the solar panel (B)
- the black cable and the red cable connected
to the charge controller (C)
[3]. Remove the fuse (D) then disconnect the cable
connecting the batteries (E).
[4]. Remove and replace the batteries.
[5]. Reconnect the cable (E) connecting the batteries
(no polarity) and refit the fuse (D).
[6]. Reconnect in the following order:
- the black cable (black - terminal) and the
red cable (red + terminal) connected to the
charge controller (C)
- the solar panel (B)
- the motor (A)
[7]. Reaffix the adhesive protectors to the terminals.
Fil rouge
2
1
3
Fil noir
MOTEUR
SGA / SGS
Freevia
GDK / LS
12V 12 Ah
D
E
C
B
- 5 -
12V 12 Ah
E
C
-
+
A
Copyright © 2009 Somfy SAS. All rights reserved.
- Seuls les outils isolés doiv
- Les batteries n'ont pas be
Toute ouverture d'une bat
- Le boîtier batterie doit tou
à gauche et sortie de câb

Publicidad

Tabla de contenido
loading

Tabla de contenido