Health Zenith 598-1041-04 Manual De Instrucciones página 4

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

TESTING
❒ Turn on the circuit breaker and light
switch.
NOTE: Sensor has a 1
period before it will detect motion.
When first turned on or when
switching modes wait 1
❒ Switch the on-time to TEST position and
Dual Brite™ switch to the OFF position.
TEST 1 5 10 MIN
ON-TIME
Avoid locations that will cause the
control to "see":
• Objects that change temperature rapidly,
such as heating vents and air condition-
ers. These heat sources could cause false
triggering.
• Areas where pets or traffic may trigger the
control.
• Nearby large, light-colored objects
reflecting light may trigger the shut-off feature.
Do not point other lights at the sensor.
1.8 m
Maximum
Range
1
/
minute warm up
2
1
/
minutes.
2
OFF 3 6 DUSK TO
HOUR DAWN
9.1 m
Maximum
Coverage Angle
The detector is less sensitive to motion directly
towards it and more sensitive to across motion.
Motion
Least Sensitive
❒ Walk through the coverage area noting
where you are when the lights turn on.
❒ If you need to change the sensitivity,
temporarily remove the fixture and make
the adjustment. Too much sensitivity
may cause false triggering in some
installations.
❒ Set the amount of TIME you want the
light to stay on after motion is detected.
(1, 5, or 10 minutes).
TEST 1 5 10 MIN
❒ Set the amount of time after dusk you
want the lights on accent level.
SPECIFICATIONS
Range . . . . . . . . . . . . . Up to 30 ft. (9.1 m) [varies
180°
Sensing Angle . . . . . . . Up to 180°
Electrical Load . . . . . . Up to 100 Watt Maximum
Sensor Capacity . . . . . Up to 360 Watt (3.0 A.)
Power Requirements . 120 VAC, 60 Hz
Operating Modes . . . . TEST, AUTO and
Time Delay . . . . . . . . . 1 , 5, 10 minutes
Dual Brite™ timer . . . . Off, 3, 6 hrs, to dawn
DESA Specialty Products™ reserves the right to
discontinue products and to change specifications at
any time without incurring any obligation to incorporate
new features in products previously sold.
4
Motion
Sensor
Most Sensitive
OFF 3 6 DUSK TO
HOUR DAWN
with
surrounding
temperature].
Incandescent
Maximum
MANUAL MODE
598-1041-04

Publicidad

Tabla de contenido
loading

Tabla de contenido