BHPC 150-1
8 Trouble-shooting
DE
EN
Please ensure that you check the following before contacting the BERNER service organization:
FR
Symptom
IT
Machine refuses to start Machine not plugged in
ES
Fluctuating pressure
Motor busses
Machine stops
Fuse blows
Machine pulsating
Machine often starts
and stops by itself
Machine starts, but
no water comes out
Pump pressure drops
In case problems other than the above occur, please contact your local BERNER distributor.
30
128303560_BHPC_150-1.indb 30
128303560_BHPC_150-1.indb 30
Cause
Recommended action
Plug in machine.
Defective socket
Try another socket.
Fuse has blown
Replace fuse. Switch off other machines.
Defective extension cable
Try without the extension cable.
Pump sucking air
Check that hoses and connections are air-
tight.
Valves dirty, worn out
Clean and replace or refer to local BERNER
or stuck
distributor
Pump seals worn out
Clean and replace or refer to local BERNER
distributor.
Low voltage or
Activate the trigger of the spray handle.
low temperature
Fuse has blown
Replace fuse. Switch off other machines.
Incorrect mains voltage
Check that the mains voltage corresponds
to specifi cation on the model tag.
Thermal sensor activated
Leave the washer for 5 minutes to cool
down.
Nozzle partially blocked
Clean the nozzle (see section 7.2)
Fuse too small
Change to an installation higher than the
amp. consumption of the machine.
You may try without the extension cable.
Air in inlet hose/pump
Allow machine to run with open trigger until
regular working pressure resumes.
Inadequate supply of
Check that the water supply corresponds to
mains water
specifi cations required (see model tag)
NB! Avoid using long, thin hoses (min. 1/2")
Nozzle partially blocked
Clean the nozzle (see section 7.2)
Water fi lter blocked
Clean the fi lter (see section 7.1)
Hose kinked
Straighten out hose.
Pump/spray handle is
Contact your nearest BERNER Service
leaking
Centre.
Pump/hoses or accessory
Wait for pump/hoses or accessory to thaw.
frozen
No water supply
Connect inlet water.
Water fi lter blocked
Clean the fi lter (see section 7.1)
Nozzle blocked
Clean the nozzle (see section 7.2)
Button for regulation of
Adjust the button to correct working pres-
pressure / water volume not sure.
correctly adjusted
Original Instructions
25-02-2011 10:34:41
25-02-2011 10:34:41