4
Front Half of Mounting
Arm. Fix this to the
Luminaire Head
Mounting Bracket
of the Trunnion
For Wall Mounting,
Keep the Keyholes
Facing Upwards During
Installation
TRUNNION WITH BUTTON
PHOTOCELL- REQUIRES USE OF
NTX-TR-PK ACCESSORY AND BUTTON
PHOTOCELL (ORDERED SEPARATELY)
STEP 1:
Plug the female end of the quick connect,
supplied with the trunnion, into the male
connector on the luminaire. Make sure the
two halves lock together. See Figure 1.
STEP 2:
Align the four holes in the front half of the
trunnion with the four tapped holes in the
luminaire housing. Attach the trunnion to the
luminaire using the (4) 5/16" (8 mm) bolts and
lockwashers supplied with the trunnion kit.
Tighten bolts to 132 in-lbs (15 N·m). See
Figure 4.
STEP 3:
Remove wiring compartment cover on
trunnion by loosening (2) screws. See Figure
4.
STEP 4:
Remove the center knockout from the cover
by striking knockout with a hammer and
punch.
STEP 5:
Remove the nut from the threaded nipple of
the photocell and insert the threaded nipple
of the photocell through the hole in the cover.
The body of the photocell and the o-ring on
the threaded nipple should remain on the
inside surface of the cover.
STEP 6:
Tighten the nut onto the exposed end of the
threaded nipple to secure the photocell to the
cover.
STEP 7:
Wire the photocell by following the wiring
instructions included with the photocell.
STEP 8:
Reattach the wiring compartment cover that
was removed in Step 3. Tighten the screws to
30 in-lbs (3.5 N·m).
NOTE: Make sure no wires are pinched.
STEP 9:
Mount the luminaire in the desired location
2 of 5
Button Photocell
(Ordered Separately)
(2) Screws
#10-24 Screws
(2) 5/16"
to Adjust the
(8 mm)
Orientation
Bolts
using (2) 3/8" (10 mm) bolts (customer
supplied) appropriate for the mounting
surface. See Figure 3.
STEP 10:
Make wiring connections to the cord leads
per the Electrical Connections section.
STEP 11:
Remove #10-24 positioning screws on both
sides of the trunnion.
STEP 12:
Loosen 5/16" (8 mm) hex head bolts located
on both sides of the
STEP 13:
Rotate
trunnion
inner and outer
STEP 14:
Insert one #10-24 screw, removed in Step
11, into matching holes of inner and outer
trunnions. Tighten screw to 30 in-lbs (35
N·m). Repeat with screw on opposite side of
trunnion.
STEP 15:
Tighten both 5/16" hex head bolts on opposite
sides of the
TRUNNION WITH TWIST-LOCK
PHOTOCELL RECEPTACLE- REQUIRES
USE OF NTX-TR-3R OR NTX-TR-
7R ACCESSORY AND TWIST-LOCK
PHOTOCELL (ORDERED SEPARATELY)
NOTE: Flood lights are not to be used as
uplights when mounted on Trunnion with
Twist-Lock Photocell.
STEP 1:
Plug the female end of the quick connect,
supplied with the trunnion, into the male
connector on the luminaire. Make sure the
two halves lock together. See Figure 1.
STEP 2:
Position luminaire to be assembled to
trunnion optic side down with mounting holes
facing towards you.
IMPORTANT: Trunnion with Twist Lock
Photocell must be oriented with twist lock
receptacle on the right side of the trunnion as
viewed from behind luminaire.
5
Mounting Arm Fix this
to the Luminaire Head
using (4) Bolts
Rear Trunnion
Bracket. Fix this
to the Mounting
Wiring
Surface
Compartment
Cover
For Wall Mounting,
Keep the Keyholes
Facing Upwards During
Installation
trunnion.
to desired tilt angle. Line up
trunnion
positioning holes.
trunnion
to 132 in-lbs (15 N·m).
(2) Adjustment
Screws for Twist
Lock Receptacle
(One Each Side of
Twist Lock)
#10-24 Screws
(2) 5/16"
to Adjust the
(8 mm)
Orientation
Bolts
STEP 3:
Align the four holes in the inner trunnion
with the four tapped holes in the luminaire
housing. Attach the trunnion to the luminaire
using the (4) 5/16" (8 mm) bolts and
lockwashers supplied with the trunnion kit.
Tighten bolts to 132 in-lbs (15 N·m). See
Figure 5.
STEP 4:
Mount the luminaire in the desired location
using (2) 3/8" (10 mm) bolts (customer
supplied) appropriate for the mounting
surface. See Figure 3.
STEP 5:
Make wiring connections to the cord leads
per the Electrical Connections section.
STEP 6:
Remove #10-24 positioning screws on both
sides of the trunnion.
STEP 7:
Loosen 5/16" (8 mm) hex head bolts located
on both sides of the
trunnion.
STEP 8:
Rotate
trunnion
to desired tilt angle. Line up
inner and outer
trunnion
positioning holes.
STEP 9:
Insert #10-24 screw, removed in Step 6, into
matching holes of inner and outer trunnion.
Tighten screw to 30 in-lbs (35 N·m). Repeat
with screw on opposite side of trunnion.
STEP 10:
Tighten both 5/16" hex head bolts on opposite
sides of the
trunnion
to 132 in-lbs (15 N·m).
STEP 11:
Twist lock receptacle must be positioned
to orient photocell between +/- 45° from
vertical. See Figure 6. If the receptacle needs
to be repositioned to orient photocell in this
tilt range, remove the screws holding the
receptacle mounting bracket to the trunnion
(See Figure 5), and reposition mounting
bracket to properly orient receptacle.
Retighten screws to 30 in-lbs (3.5 N·m) after
repositioning bracket.
STEP 12:
Install twist lock photocell or shortening cap
(ordered separately).
LPN00630X0002A0_C
Twist Lock
Photocell
Receptacle