Céliane™
Radio lighting scenario switch
672 38
Technical data
Power supply 1 lithium battery
CR2032
Radio
868.3 MHz
Frequency
about 200 m
Range
in free field
+ 5°C to + 45°C
Factory settings
When first powered up, pressing the ON/+ or
OFF/- buttons controls all the lighting recei-
vers by default.
This option is provided so that the correct
operation and connection of all the lighting
fixtures can be checked.
(1)
Pressing Learn
twice cancels this general
control function.
(1)
Programming or learning button.
Description
Control
button
Strictly comply with instructions for installation and use
9
Operation
The radio lighting scenario switch is a transmitter (leader) that enables
control of two sets of receivers (actors) associated with it during lear-
ning.
Using the ON/- and OFF/+ buttons allows to :
- switch on by a short press on the ON button
- switch off by a short press on the OFF button
Dimming (when combined with a dimmer) :
- increasing light level by a long press on button ON
- decreasing light level by a long press on button OFF
Only ON button learning is necessary, the OFF button is learnt
automatically.
Note :
This "In One by Legrand" product can be linked to PLC products by
means of the PLC/RF modular interface (Cat. No. 036 06).
10
Control
button
LEARN
indicator
LEARN
button