PROGRAMMING FLOWCHART
Entering Menu is always done with B + 000000 if the Master Code is not changed.
Submenu 1 - Change Master Code. The Master Code must be 6 digits. After enrolling new Master Code
the PADPROX-EH automatically exits the Menu and the new master code must be typed to enter the
menu.
Submenu 2 - Select Type of Wiegand. With this the Keypad can be adjusted to send 7 different
Wiegand Outputs. The Wiegand selected must be the same as the controller's Wiegand Input where the
PADPROX-EH Keypad is being connected. Example: If you use a controller that recognizes
Wiegand 34bit, then enter the menu of PADPROX-EH, press 2, then press 3.
Submenu 3 - Select Output Protocol. The Keypad can send the Code by different Protocols.
Use "Single Wiegand" when connected to third party controllers. When "Single Wiegand" is selected,
what is typed on the Keypad the same will be sent as Wiegand Number. Use Double Wiegand when
connected to EWS, use Clock&Data when connected to controller with Clock&Data input.
Submenu 4 - PIN Code Length. If "0" is selected, then any PIN Code with any length can be sent, but
the PIN Code is typed with "A" for confirmation( ex. 123 + A). If 1 to 8 is selected the PIN Code length is
determinated by the number selected.
Submenu 5 - Entry Mode. "Only PIN Code" is disabling the proximity and PADPROX-EH works as keypad
only. "Only Card" is disabling the Keypad and the PADPROX-EH works as Proximity Reader. "Card and PIN
Code" defines the double security, both the Card and PIN Code is required for the Wiegand to be sent.
"Card or PIN Code" enables normal operation.
Submenu 6 - Presets. The Presets are set of preprogrammed parameters for easy programming.
6-1 "Wiegand 26bit Normal" -
Type: Wiegand 26bit; Output: Single Wiegand; PIN Length: 4 digits; Entry Mode: Card or PIN Code
6-2 "Wiegand 34bit Normal" -
Type: Wiegand 34bit; Output: Single Wiegand; PIN Length: 4 digits; Entry Mode: Card or PIN Code
6-3 "Wiegand 34bit EWS Mode" -
Type: Wiegand 34bit; Output: Double Wiegand; PIN Length: 4 digits; Entry Mode: Card or PIN Code
6-4 "Wiegand 26bit EWS Mode" -
Type: Wiegand 26bit; Output: Double Wiegand; PIN Length: 4 digits; Entry Mode: Card or PIN Code
Submenu 7 - Site Code Length. Set the code length sent to Host. Default is "0". To be used only in
specific cases.
Submenu 8 - Enter Site Code. Put the site code always in 5 digit format (ex. 00170).
Submenu 9 - Backlight, Buzzer, Parity. Turns ON/OFF the backlight.