Cooper Lighting Streetworks Archeon Large Instrucciones De Instalación
Cooper Lighting Streetworks Archeon Large Instrucciones De Instalación

Cooper Lighting Streetworks Archeon Large Instrucciones De Instalación

Publicidad

Idiomas disponibles

Idiomas disponibles

Enlaces rápidos

IB521010EN
Installation Instructions - Archeon
Instructions d'installation – Archeon
Instrucciones de instalación - Archeon
WARNING
Make Certain Power is OFF before starting installation
or attempting any maintenance.
WARNING
Risk of Fire/Electric Shock. If not qualified, consult an
electrician.
WARNING
Risk of Electric Shock – Disconnect power at fuse or
circuit breaker before installing or servicing.
WARNING
Risk of Personal Injury – Fixture may become damaged
and/or unstable if not installed properly.
Do not mount luminaire within 6" of a combustible
surface.
Do not handle luminaire by the glass. Do not touch
LEDs.
IMPORTANT: Read carefully before installing fixture. Retain for future reference.
GENERAL: Upon receipt of the fixture, thoroughly inspect for any freight damage which should be brought to the
attention of the delivery carrier. Compare the catalog description listed on the packing slip with the fixture label on the
housing to assure you have received the correct material.
SAFETY: This fixture must be wired in accordance with the National Electrical Code and applicable local codes and
ordinances. Proper grounding is required to insure personal safety. Carefully observe grounding procedure under
installation section.
APPLICATIONS: This lighting fixture is designed for outdoor lighting services, and should not be used in area of limited
ventilation or inside high ambient temperature enclosures. It must be stored in a dry location prior to installation. Do
not expose lighting fixture to rain, dust or other environmental conditions prior to installation and insertion of photo
control or shorting cap (if so equipped). Do not install the fixture near combustible materials or locate next to airflow
blocking surfaces within 6 inches. Best results will be obtained if installed and maintained according to the following
recommendations.
Large
TM
Large
MC
Large
TM
WARNING
Risk of Burn – Disconnect power and allow fixture to
cool before servicing.
N
ote:
These instructions do not claim to cover all
details or variations in the equipment, procedure,
or process described, nor to provide directions
for meeting every possible contingency during
installation, operation or maintenance. When
additional information is desired to satisfy a
problem not covered sufficiently for user's purpose,
please contact your nearest representative.
N
ote:
This lighting fixture has been shipped complete
with one of several mounting options. Please follow
the installation instructions specific to the catalog
part that you ordered.
N
ote:
Care must be taken not to set lighting fixture down
on optical lenses or lift the fixture in the lens area.
Specifications and dimensions subject to change
N
ote:
without notice.
Brand Logo
reversed out of
black
INS #
INS #

Publicidad

Tabla de contenido
loading

Resumen de contenidos para Cooper Lighting Streetworks Archeon Large

  • Página 1 Brand Logo reversed out of black IB521010EN INS # INS # Installation Instructions - Archeon Large Instructions d’installation – Archeon Large Instrucciones de instalación - Archeon Large WARNING WARNING Make Certain Power is OFF before starting installation Risk of Burn – Disconnect power and allow fixture to or attempting any maintenance.
  • Página 2: Tools Required

    Figure 2. Using a 9/16” socket, tighten the clamp bolts to 16-18 ft-lbs. Door Latch Bird Guard (4) Bolts 3/8” (2) Pipe Clamps Cutout for Larger Diameter Arm Figure 3. Leveling Steps Figure 1. COOPER LIGHTING SOLUTIONS IB521010EN Installation instructions...
  • Página 3 (Figure 7 .). Align holes top and bottom. Square Pole Insert the mast arm onto the threaded rods thru the top and bottom holes. Figure 6. Install washers, nuts and Torque nuts using 1/2” open wrench to 35~40 ft-lbs. COOPER LIGHTING SOLUTIONS IB521010EN Installation instructions...
  • Página 4 Slot for North or other contaminants. Additional cleaning can be performed with using a non-abrasive polycarbonate cleaner. Remove any dirt, leaves or other foreign debris from the housing. Figure 9. COOPER LIGHTING SOLUTIONS IB521010EN Installation instructions...
  • Página 5: Outils Requis

    (Figure 3). 1/4 de tour. Il est possible d’enlever la porte en l’ouvrant à environ 120°, en la soulevant hors de la charnière et en débranchant la tirette de largage verte. COOPER LIGHTING SOLUTIONS IB521010EN Instructions d’installation...
  • Página 6 Loquet Crans de nivellement Dispositif de protection contre les oiseaux (4) boulons de 9,5 mm (3/8 po) Figure 2. (2) Brides de serrage Crans de nivellement Figure 1. Entrée défonçable pour diamètre de bras plus grand Figure 3. COOPER LIGHTING SOLUTIONS IB521010EN Instructions d’installation...
  • Página 7 Vissez-les sur l’écrou d’ancrage. Poteau carré Pour les poteaux ronds seulement – installez la plaque d’adaptation ronde en plaçant le côté rond face au poteau (Figure 7). Alignez les trous supérieurs et Figure 6. inférieurs. COOPER LIGHTING SOLUTIONS IB521010EN Instructions d’installation...
  • Página 8 Un nettoyage supplémentaire peut être effectué à l’aide d’un nettoyant pour polycarbonate non abrasif. Enlevez toute la saleté, Figure 9. toutes les feuilles et tous les débris du boitier. COOPER LIGHTING SOLUTIONS IB521010EN Instructions d’installation...
  • Página 9: Instalación

    Con la carcasa sobre una superficie lisa y suave, abra la puerta de acceso girando el pestillo frontal 1/4 de vuelta. La puerta se puede quitar abriéndola aproximadamente 120° y levantándola de la bisagra mediante la desconexión del cordón de alambre verde. COOPER LIGHTING SOLUTIONS IB521010EN Instrucciones de instalación...
  • Página 10 (2) Abrazaderas del tubo Protección contra pájaros Pasos de nivelación (4) pernos de 3/8” (2) Abrazaderas del tubo Figura 2. Pasos de nivelación Figura 1. Recorte el brazo de mayor diámetro Figura 3. COOPER LIGHTING SOLUTIONS IB521010EN Instrucciones de instalación...
  • Página 11 Atornillar en la placa de tuerca. Figura 6. Solo para postes redondos: instale el adaptador de la placa redonda con el lado curvo hacia el poste (Fig. 7). Alinee los orificios superior e inferior. COOPER LIGHTING SOLUTIONS IB521010EN Instrucciones de instalación...
  • Página 12: Mantenimiento

    Se puede realizar una limpieza adicional con el uso de un limpiador no abrasivo al policarbonato. Eliminar la suciedad, hojas u otros residuos extraños de la carcasa. Figura 9. COOPER LIGHTING SOLUTIONS IB521010EN Instrucciones de instalación...
  • Página 13: Garantías Y Limitación De Responsabilidad

    Veuillez consulter le site www.cooperlighting.com/legal pour obtenir les conditions générales. Garantías y Limitación de Responsabilidad Visite www.cooperlighting.com/legal para conocer nuestros términos y condiciones. Cooper Lighting Solutions 1121 Highway 74 South Cooper Lighting Solutions is a Peachtree City, GA 30269 registered trademark. P: 770-486-4800 All trademarks are property www.cooperlighting.com...

Este manual también es adecuado para:

Streetworks archeon medium

Tabla de contenido