Crimping
1 Insert the connector in the tool's crimp bay until it
touches the end stop. Insert the cable into the con-
nector.
2 Press the handles together until the trigger mecha-
nism is released. Open the tool and remove the as-
sembled cable.
CAUTION
To avoid damaging the tool, be sure not to
crimp on the plug gauge or other similar ob-
jects. You should never crimp solid materi-
als (such as steel) with a hardness exceed-
ing 35 HRC.
Changing the locator (see also Fig. 1)
• Loosen the fastening screw from the locator with an
allen key 2,5 mm, maybe use a second allen key for
retain the allen screw on the opposite of the tool
• Remove locator
• Fix an optional locator vice versa
Battery replacement
The service life of the digital display's battery is ap-
proximately one year, depending on use.
Battery replacement: Open up the battery compart-
ment. Remove the old battery. Insert the new battery
and close compartment. To do this, ALWAYS set the
tool all the way to its lowest setting BEFORE chang-
ing the battery.
After replacing the battery or opening the battery com-
partment, you must reset the tool and adjust the set-
tings where necessary.
Reset / Tool adjustment
CAUTION
Adjustments to the crimping tools should
only be carried out by an authorized techni-
cian, since improper adjustments can lead
to faulty crimps.
1 Using the dial, adjust the crimping die so that the
supplied plug gauge fits snugly into the space be-
tween the crimping spikes. In the process you
should make sure that the set size of the plug
gauge is always adjusted starting from a greater
value (for example, starting from 2.4 mm and going
down to a 2.0-mm plug gauge size).
2 Press the „ON" button and keep is pressed down. At
the same time, press the „MODE" button using the
plug gauge. Keep the „MODE" button pressed down
for at least four seconds. First release the „MODE"
button and then the „ON" button.
3 The digital display automatically jumps to a 2.0-mm
plug gauge value (shown as 0.00 in the digital dis-
play).
4 You may now set the crimping parameters.