4.6
Using the electricity supplied
1.
Allow the unit speed to stabilise and the temperature to rise (approx. 3 to 5 min.).
2.
If the choke (A6) was used, return it gradually to its original position.
3.
Connect the equipment to be used to the electrical sockets (A8) on the unit.
For France only: Our generating sets are fitted with European (Schuko type) sockets where the earthing contact is made using side
tabs. In exceptional cases where your units require the use of earthing pins, we supply* a 16 A pin adaptor (compliant with
NF C 61-314).
*Contact our sales department on 0 825 004 002 (calls charged at €0.15 per min inc. tax) and provide proof of purchase.
After use, always disconnect the adaptor and store it carefully, away from sources of humidity. Always
ensure that the socket cover on the generating set is closed: risk of damage (loss of seal).
IMPORTANT
Schuko type
generating set
socket, with cover.
4.7
Switching the generating set off
1.
Disconnect the equipment used, taking care to close the cover for the unit's electrical sockets (A8).
2.
Allow the unit to run idle for 1 or 2 minutes.
3.
Set the switch (A5) to "OFF" or "O ": the unit will shut down.
4.
Close the fuel tap (A4).
Always make sure that the unit is correctly ventilated.
Even when the unit is turned off, the engine continues to give off heat.
IMPORTANT
5 Generating set maintenance
As a safety measure, maintenance should be performed on the generating set regularly and carefully by people who have the
necessary experience and are equipped with suitable tools, in respect of current regulations. The maintenance operations to be
carried out are detailed in the maintenance table. The interval for this is supplied as a guide and for generating sets operating with
fuel and oil which conform to the specifications given in this manual. The maintenance intervals can be shortened depending on the
generating set's operating conditions and requirements. It is important to note that the warranty shall not be valid if generating set
maintenance has not be performed correctly.
5.1
Reminder of use
Ensuring maintenance is performed regularly and correctly will guarantee safety and performance. The oil, filter elements and,
where present, the spark plug, are consumables which must be in good condition for the unit to operate correctly.
Replace them regularly as often as is needed (the reference for ready-to-use maintenance kits is given in the table of
technical specifications where applicable). The warranty becomes void in the event of failure to respect the maintenance
recommendations. For any questions about a special operation, please contact your nearest agent who will advise and help you.
5.2
Maintenance intervals table
Operation to be carried out at whichever deadline is
reached first:
Clean the unit
Unit
Clean the spark arrester
Replace the spark plug
Oil
Clean the screen filter
Fuel
Clean the sediment bowl
Air filter
Part numbers of parts to be used during maintenance:
French plug
NF C 61-314
Use the adaptor
After the:
Change
Clean
Replace
Every
3 months/50
first 5 hours
hours
X
X
Mixed plug
No need to use
adaptor
Every
Every
1 year/100
2 years/200
hours
hours
X
X
General
X
maintenance
must only be
X
carried out by
X
one of our
agents.
X
France:
X
0.806.800.107
X
(call charge)
R18