8 Technical specifications

8.1

Operating conditions

The stated outputs of the units are obtained under the reference conditions outlined in ISO 8528-1(2005):
Total barometric pressure: 100 kPa - Ambient air temperature: 25°C (298 K) - Relative humidity: 30%.
The unit's output is reduced by approximately 4% for every additional 10°C and/or approximately 1% for every additional 100m in
altitude. Units can only operate while stationary.
8.2
Capacity of the generating set
Before connecting and operating the unit, calculate the electrical power required by the units to be used (in watts)*. To ensure
optimal operation, the total wattage of all equipment used at the same time must be:
-
greater than 60% of the rated load for the unit (risk of insufficient load);
-
less than the rated load for the unit during continuous operation (risk of overload).
If the unit is run under or over its rated load frequently or for long periods of time, it can start to wear very quickly. Damage caused
in this way will not be covered by the warranty.
*This load is usually indicated in the technical specifications or on the manufacturer's plate for the equipment. Some equipment
requires a higher load when starting. This minimum required power must not exceed the unit's maximum power.
8.3
Generating set identification
The identification plate for the unit (example shown below) is affixed inside one of the skirts or on the chassis.
(B)
(C)
Serial numbers will be required when requesting troubleshooting advice or spare parts. For your records, please enter the unit and
engine serial numbers below.
Unit serial number:
....../.............. - ........................... - .........
8.4
Specifications
Model
Maximum power
Rated power
Acoustic pressure at 1 m
Acoustic
measurement
uncertainty
Engine type
Maintenance kit
Recommended fuel
Fuel tank capacity
Recommended oil
Oil sump capacity
Oil cut-out*
Direct current
Alternating current
Circuit breaker(s)**
Socket type
Type of spark plug
Battery
Dimensions l x w x h
Weight (without fuel)
o: standard
*Oil cut-out: If there is no oil in the engine sump or if the oil pressure is low, the oil cut-out mechanism automatically stops the engine to prevent any
damage. If this occurs, check the engine oil level and top it up if necessary before looking for any other cause of the problem.
**Circuit breaker: The unit's electrical circuit is protected by one or more magnetothermal, differential or thermal cut-out switches. In the event of an
overload and/or short circuit, the supply of electrical energy may be cut. If necessary, replace the unit's circuit breakers with components with the
same ratings and characteristics.
(G)
(D)
(E)
(H)
(I)
(F)
(A)
HX 3000 C
3000 W
2400 W
83,82 dB(A)
0,7 dB(A)
GX200
R18
Unleaded petrol
3,1 L
SAE 15W40
0,6 L
o
X
230V - 10,4A
o
2x2P+T 230V 10/16A
330830005
X
59 x 46 x 43 cm
41 kg
X: not available
(A):
Model
(B):
CE/EAC marking
(C):
Guaranteed acoustic
(J)
power level
(D):
Maximum power
(K)
(E):
Nominal power
(L)
(F):
Power factor
(M)
Engine manufacturer:(e.g.
Kohler)
........................................
HX 4000 C
4000 W
3200 W
86,43 dB(A)
0,7 dB(A)
GX270
R19
Unleaded petrol
5,3 L
SAE 10W30
1,1 L
o
X
230V - 13,9A
o
1x2P+T 230V 10/16A /
2x2P+T 230V 10/16A
330830005
X
71,5 x 57 x 49 cm
56 kg
(G):
Ground
(H):
Current amperage
(I):
Current frequency
(J):
Current voltage
(K):
Protection rating
(L):
Reference standard
(M):
Serial number
Engine serial number: (e.g Kohler (SERIAL
NO. 4001200908))
......................................................
HX 6000 C
6000 W
4800 W
86,03 dB(A)
0,7 dB(A)
GX390
R19
Unleaded petrol
6,1 L
SAE 10W30
1,1 L
o
X
230V - 20,9A
230V - 10A / 400V - 7A
o
1x2P+T 230V 10/16A /
1x2P+T 230V 32A
1x3P+N+T 400V 7A
330830005
X
71,5 x 57 x 59 cm
75 kg
HX 7500 T C
6000 W
4800 W
86,03 dB(A)
0,7 dB(A)
GX390
R19
Unleaded petrol
6,1 L
SAE 10W30
1,1 L
o
X
o
330830005
X
71,5 x 57 x 59 cm
76 kg

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Hx6000cHx7500tcHx4000c

Tabla de contenido