38/144 Bosch Rexroth AG
5 Menus when connecting the SD301 to a SE31x/SEH312
5.2
Process
This menu contains the Tightening pro-
grams menu item.
5.2.1
Tightening programs
This menu allows you to change the tighten-
ing parameters. When doing this, the pro-
gram structure from the last program
accessed is displayed.
1
Fig. 18:
The display is divided into:
1 – Program selection
2 – Step selection
3 – Program information
4 – +- Send button.
Pressing the Program selection (1) button
calls up a list of the available tightening pro-
grams (Fig. 18).
Pressing the Step selection button (2) calls
up a list of tightening steps for the current
program.
Pressing the Info button (3) displays addition-
al program information.
Pressing the +- button (Send) sends a pro-
gram to the controller.
If, for example, program 02 is pressed
(Fig. 18), it is displayed in its tightening
steps:
2
3
4
SD301 | 3 609 929 826/06.03
Fig. 19:
Pressing the tightening step, e.g. 3,A
(Fig. 19) displays the step's parameters:
Fig. 20:
Pressing the parameter value, e.g.
17,000 Nm (Fig. 20) opens up the key pad
(see chapter 4) used to change the value:
Fig. 21:
Pressing the Enter button transfers the value
to the program.