Enerpac PA-133 Manual De Instrucciones página 2

Ocultar thumbs Ver también para PA-133:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 19
SPECIFICATIONS
Model No.
Air Pressure
Air Consumption
Oil Flow at 100 psi air
Usable Oil Capacity
Weight
dBa
INSTALLATION
Adding Oil to the Reservoir
1. Hold pump on end as shown in Figure 1 and remove
2. Fill to
Attempting to overfill the reservoir will cause the reservoir to become pressurized.
If the reservoir is subjected to high pressure, the casing may rupture, causing
personal injury and/or equipment damage.
3. Replace the fill plug and finger tighten.
DO NOT use a wrench. Over-tightening will tear the reservoir bladder.
4. Tip the pump and check for leakage. If leakage occurs, remove the plug and check
5. Replace the fill plug making sure the seal is centered properly on the plug. If leakage
PA-133, 7001
40 cu. in./min. at 0 psi [656 cu. cm/min at 0 bar]
8 cu. in./min. at 10,000 psi [131 cu. cm/min at 700 bar]
36 cu. in.
[590 cu. cm]
12 lb. [5,45 kg]
fill plug. On PA-1150 models, the fill plug is located
on the side of the pump as shown in Figure 2.
Figure 2
1
/
" [1 cm] below the fill opening with Enerpac hydraulic oil. Use of fluids
2
other than Enerpac hydraulic oil may cause damage and will void your warranty.
WARNING
CAUTION
the plug seal for cuts or nicks. Replace the seal if necessary.
still occurs, remove oil and take pump to your nearest Enerpac Service Center.
PA-166
60 - 100 psi [4,1 - 6,9 bar]
3
9 CFM [15 m
/h]
72 cu. in.
[1180 cu. cm]
16 lb. [7,27 kg]
85 dBa
2
PA-1150
80 cu. in.
[1311 cu. cm]
18 lb. [8,18 kg]
Figure 1

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Pa-166Pa-11507001

Tabla de contenido